Step 4: Power Control Wiring
When wiring to a wall switch, follow the directions in the manual provided with that product. When
wiring to an Omni control relay or an Omni Smart Relay, refer to the graphics below. Be sure to follow
all NEC and local codes when wiring.
Load 1 out
Red/White
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Omni Standard Relay Wiring
Omni Smart Relay Wiring
Neutral
Black/White
Red
Line 1 in
Neutral
Black
Gray
Hot (black)
Connection to transformer
Neutral (white)
Connection to transformer
Ground (green)
Connection to transformer