Fault
The inspection flap does not
close/does not remain
closed.
The DuoClean is swivelling
excessively.
The DuoClean causes streaks/
marks on the floor.
The DuoClean is not
vacuuming effectively.
62
Possible cause and solutions
It is possible that the tank is not correctly installed.
– Switch the cordless vacuum cleaner off.
– Install the tank, see
[} 52].
– Switch the cordless vacuum cleaner back on again.
It is possible that the holding magnet is dirty.
– Switch the cordless vacuum cleaner off.
– Clean the surface of the magnet.
It is possible that the suction channel is still wet.
– Switch the cordless vacuum cleaner off.
– Using a kitchen towel, dry the area of the suction channel that
is exposed by the inspection flap
.
– Let the suction channel dry before continuing.
The cleaning cloth is not fixed properly.
– Check whether the cleaning cloth is straight and firmly fixed on
the cloth holder frame.
– Check whether the green nose of the cleaning cloth has been
correctly and fully pushed in.
The cloth holder frame is not inserted correctly.
– Check whether the cloth holder frame has attached itself
correctly to the DuoClean.
– It is possible that original Kobold cleaning cloths were not used.
– Only use original Kobold cleaning cloths.
– Use the Kobold MF600/601 Universal cleaning cloth on rough
surfaces.
It is possible that the sealing lip frames are dirty and jammed.
– Remove the front sealing lip frame, see
the sealing lip frames
It is possible that the cleaning cloth is soiled excessively.
– Change the cleaning cloth, see
[} 58].
It is possible that the sealing lip frames are dirty and jammed.
– Remove and clean the sealing lip frames, see
cleaning the sealing lip frames
– Also check whether the suction openings between the sealing
lips are clear from underneath. If necessary, shake out any
objects inside.
Removing, filling and inserting the tank
[} 59].
Replacing the cleaning cloth
[} 59].
Checking and cleaning
Checking and