1. Fix the wheel balancer after removing it from its packing.
2. Set the grounding line.
3. Do not move the main shaft and avoid any breakage.
4. Avoid humidity and vibration effects.
5. It is advisable to use a stable power supply.
PRESETTING THE THREE
STORED DATA VALUES
Note: this function can be used only when the balancing nuts are not precise and stable
even after calibration. When these three values are being adjusted, remove the 100-g
weight, perform calibration after setting each of the three values to store them in the
computer, otherwise this function will not be effective. Remove the weight tray and
consult the original data indicated inside the machine for setting.
1) SFA data adjustment: after calibration, if the 100-g weight is not positioned directly
under the wheel-holder shaft (six o'clock position) or if data are not correct, this function
can be used to determine the weight offset value. Remove the weight, then press the
and
"A"
button, then rapidly the value "A"
press the
the values; it is not necessary to pay attention to them; press the value "A"
ton again (the
is displayed on the left, the corresponding value is displayed on the right; then press
the value "A"
100-g weight position. If the data is to be modified, press the value "L"
button to adjust the 100-g offset value, then press the value "A"
Repeat calibration. Sometimes the SFA value must be re-adjusted until the 100-g weight
is not positioned directly under the wheel-holder shaft.
2) "dis" value adjustment: this function is used for solving the internal unbalance value
problem.
Balance the wheel and apply a 100-g weight on the outside of the tyre. The value dis-
played ranges between 104 and 96. Move the 100-g weight to the inside of the tyre. After
stopping, the value ranges between 104 and 96, i.e. normal value. If not, the operator
should adjust the "dis" value; the adjusting procedure is the same as that used for the
Operator's manual @ 601
button; indicators stop flashing after nine seconds; press the value
button; the left indicator displays "dis", the right indicator displays
button now allows the operator to go to the next program); "In-l"
button to go to the SFA window. The right indicator displays the
button. When all indicators are off,
but-
GB
or
button to exit.