MS900 stand
Remove all the cleaning products from the hydrocyclone housing.
Then reassemble the hydrocyclone in the reverse order of disassembly, close the valve (item 1 in
Figure 14), and place the stand panels back in their position.
7.3. Checking and cleaning the three-way valve
To check the operation of the VMR 25 three-way valve (item 1 in Figure 16) of the MS900B module,
follow these steps:
Figure 16. Location of the VMR 25 three-way valve.
1. Go to the "Service" menu.
2. Open the door with the touch panel.
3. In the "Service" menu, press the "Valve direction water" button several times (refer to Figure 17)
and observe how the indicator moves on the VMR 25 valves (refer to Figure 18). In a properly
functioning valve, the indicator moves smoothly and always returns to its original position. If
there are deviations in the movement of the indicator (usually sticking in the middle position), it
requires cleaning.
20