Battery PAP 20 B3*
Type
Rated voltage
Capacity
Cells
High-speed battery charger PLG 20 C3*
INPUT
Rated voltage
Rated power
consumption
Fuse (internal)
OUTPUT
Rated voltage
Rated current
Charging time
Protection class
* BATTERY AND CHARGER ARE NOT INCLUDED
ATTENTION! Hot surface.
There is a risk of burns.
Noise emission value
Noise measurement value determined in accord-
ance with EN 62841. The A-rated noise level of
the power tool is typically as follows
Hammer-drilling
Sound pressure level
Uncertainty
Sound power level
Uncertainty
Total vibration value
Total vibration values (vector total of three direc-
tions) determined in accordance with EN 62841:
(main handle)
Hammer-drilling a
h.HD
Chiselling
a
h,CHeq
(additional handle)
Hammer-drilling a
h, HD
Chiselling
a
h,CHeq
PKHAP 20-Li C3
LITHIUM ION
20 V
(DC)
4 Ah (80 Wh)
10
230–240 V ~ , 50 Hz
(AC)
120 W
T3.15A
3.15 A
21.5 V
(DC)
4.5 A
approx. 60 min
II /
(double insulation)
L
= 101.9 dB (A)
pA
K =
3
L
= 112.9 dB (A)
WA
K =
3
= 6.449 m/s
2
, K = 1.5 m/s
= 6.498 m/s
2,
K = 1.5 m/s
= 10.089 m/s
2
, K = 1.5 m/s
= 8.776 m/s
2,
K = 1.5 m/
NOTE
►
The vibration emission values and the noise
emission values given in these instructions
have been measured in accordance with a
standardised test procedure and can be used
for comparison of the power tool with
another tool.
►
The specified total vibration values and the
noise emission values can also be used to
make a provisional load estimate.
WARNING!
►
Depending on the manner in which the
power tool is being used, and in particular
the kind of workpiece that is being worked,
the vibration and noise emission values can
deviate from the values given in these instruc-
tions during actual use of the power tool.
►
It is necessary to establish safety measures to
protect the operator based on an estimation
of the vibration load during actual use (all
states of operation must be included, e.g.
times when the power tool is switched off and
times where the power tool is switched on but
running without load).
dB
dB
2
2
2
GB │ IE
│
3
■