Descargar Imprimir esta página

Nice S4BAR Instrucciones Y Advertencias Para La Instalación Y El Uso página 5

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 63
2
PRODUCT DESCRIPTION
AND INTENDED USE
S4BAR is an electromechanical road barrier for residential use; it controls ope-
ning and closing of a road transit point with widths up to 3 metres .
CAUTION! – Any uses other than those specified herein or in environ-
mental conditions other than as stated in this manual are to be consid-
ered improper and are strictly prohibited!
S4BAR is an electromechanical gearmotor with a 24 V motor, with optional
flashing light signal (XBA7) and electric limit switch system. The control unit is
set up for connected to devices belonging to the Nice Opera system and con-
nection to the solar power system "Solemyo" (see paragraph 4 .10 .3) .
S4BAR runs on electric energy and in the event of a power failure the pole can
be released and moved manually . Alternatively the buffer battery model PS124
can be used (optional accessory - see paragraph 4 .10 .2), which guarantees a
number of automation manoeuvres in the first few hours of power failure. To
prolong this period or extend the number of manoeuvres, the Stand by function
should be enabled (see table 6) .
S4BAR is also designed for installation of the pole lights, mod. XBA4 (acces-
sory - see paragraph 4 .8) .
3
INSTALLATION
3.1 - Preliminary checks for installation
Before proceeding with installation, check the condition of the product compo-
nents, suitability of the selected model and conditions of the intended installa-
tion environment .
• Ensure that all material used is in perfect condition and suitable for use .
• Ensure that all product application limits can be observed (see paragraph
3 .2) .
• Ensure that the selected installation environment is compatible with the over-
all dimensions of the product (fig. 2) .
• Ensure that the selected surfaces for barrier installation are solid and guaran-
tee a stable fixture.
• Make sure that the fixing zone is not subject to flooding. If necessary, mount
the barrier raised from the ground .
• Ensure that the space around the barrier enables easy and safe completion
of manual manoeuvres .
• Ensure that there are no obstacles along the pole trajectory which prevent the
opening and closing manoeuvres .
• Ensure that each device to be installed is in a sheltered location and pro-
tected against the risk of accidental impact .
3.2 - Product application limit
Before installing the product, ensure that all values specified in the chapter
"Technical product specifications" and maximum cycle frequency as stated in
Table 1 are compatible with the intended use .
– Ensure that the estimated durability (see paragraph 3 .2 .1) is compatible with
the intended use .
– Ensure that all limits, conditions and warnings in this manual can be
observed .
Product Type
Maximum
speed
S4BAR with XBA19
pole, impact protec-
V5
tion rubber XBA13,
without accessories
S4BAR with XBA19
pole, impact protec-
V4
tion rubber XBA13
and lights mod. XBA4
3.2.1 - Product durability
The lifetime is the average economic duration of the product . The value of life-
time is strongly influenced by the intensity of the manoeuvres, i.e. the sum of all
factors that contribute to product wear (see Table 2) .
To estimate the lifetime of your automation, proceed as follows:
01. Add the values of the items in Table 2 regarding the system conditions;
02. In Graph 1 from the value obtained above, trace vertical line until it inter-
sects the curve; from this point trace a horizontal line until it intersects the
line of the "manoeuvre cycles" . The obtained value is the estimated lifetime
of your product .
The lifetime values specified in the graph are only obtainable if the maintenance
schedule is strictly observed (see chapter "Maintenance schedule") . The esti-
mation of lifetime is made on the basis of design calculations and the results of
tests performed on prototypes . As it is only an estimation, it does not represent
any form of guarantee on the effective lifetime of the product .
TABLE 1
Maximum work
Maximum
cycles per hour
consecutive
work cycles
100
80
Pole with lights mod. XBA4
Ambient temperature above 40°C or below 0°C
Presence of dust or sand
Presence of saline mist
Interruption of manoeuvre via Foto > 10%
Interruption of manoeuvre via Alt > 10%
Force equal to 5 or 6
Force equal to 7 or 8
V3 and V4 speed
Speed V5
500.000
400.000
300.000
200.000
100.000
Example of calculating lifetime of road barrier S4BAR (refer to Table 2 and
Graph 1):
S4BAR with lights XBA4 (severity index of 15%) - Presence of saline mist (severity
index of 10%): Total severity index = 25%
The estimated durability is approx. 240,000 manoeuvre cycles.
3.3 - Typical system
Fig. 3 shows the components in the product pack:
[a] - road barrier with built-in control unit
[b] - pole support
[c] - pole plug
[d] - 2 pole joining brackets
[e] - metal hardware (screws, washers, etc . keys for manual locking and release
of the pole)
[f] - fixing bolts
[g] - photocell box
[h] - foundation plate
Fig. 1 shows an example of an automation system set up with Nice compo-
nents . With reference to the typical standard layout in fig. 1, locate the approxi-
mate position for installation of each component envisaged in the system .
50
CAUTION! – In general, position the ends of the ducting used for elec-
trical cables in the vicinity of the points envisaged for fixture of the
various components. Note: The ducting serves to protect electric cables and
prevent accidental damage, such as in the case of impact .
40
The barrier is factory set for the closing manoeuvre to the left; in this
phase, it is important to decide whether the opening direction of the pole is to
be inverted . If Closure to the right is required, see paragraph 3.3.1.
Prepare the electrical cables needed for your system, referring to fig. 1 and
"Table 3 - Technical specifications of electrical cables" .
TABLE 2
GRAPH 1
Severity index (%)
Severity
Index
15 %
15 %
10 %
10 %
15 %
25 %
10 %
10 %
5 %
20 %
English – 3

Publicidad

loading