Descargar Imprimir esta página

Tool Up SPARK MIG 110 Manual Del Usuario página 14

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 23
ADVICE AND THERMAL PROTECTION
- Respect the normal rules of welding
- Leave the machine plugged in after welding to allow it to cool
- Thermal Protection : The LED will illuminate. Cooling will take between 10 and 15 minutes depending on the
ambient temperature.
- The excessive bending of the cable will disrupt the wire feed.
- The torch cable must be maintained in a straight position throughout inner liner loading to avoid permanent da-
mage.
- Thermal protection: the indicator lights up and the cooling time is 5 to 10 minutes depending on the ambient tempe-
rature.
Splashes :
- During welding, the spatters can easily damage the torch and welding equipment. To avoid constraints to the cable,
the welding arc's stability. Any spatter on the nozzle or difuser should be cleaned as soon as possible.
- The spatters accumulated in the nozzle that are not cleaned in due course will cause a short-circuit which could
damage the torch elements.
- The use of anti-spatter agenst to reduce the spatters is recommended. In order to avoid to deteriorate the torch,
do not use a cutting tool to clean th splashes.
- The torch mustn't be used for heating and cutting.
- The torch cable mustn't be used for pulling heavy objects (such as the welding station).
- The torch must be clean and tidy when the welding operation has ended.
- If the torch is not used for more than one week, the welding wire must be removed to avoid the increase of friction
inside the intern sheath wire (by wire oxidation).
- Additonal external protections are necessary when the torch is used in the following cases:
a. High risk of electric shock ;
b. Combustible environment ;
c. Work position at height ;
d. Noisy environment ;
e. Environment with airstream ;
f. Closed tanks.
TECHNICAL CHARACTERISTICS OF THE TORCH
Process
Guide method
Nominal/Peak voltage
Max Welding current (A)
Operating factor to 40°C
Diameter of the applicable welding wire
Cable length
Type of gas
Gas flow rate (l/mn)
Cooling mode
Applied standard
RISK OF INJURY DUE TO MOVING PARTS
The wire feeders contain moving parts that may catch hand, hair, clothes or tools which can lead to injuries!
Take extra care.
• Do not lay a hand to swivel or moving components or parts to the drive!
• Ensure that the housing covers or protective covers remain closed during operation!
14
SPARK MIG 110
Imax
EN
MIG/MAG
Manual
113 V
80 A
35%
Ø0.6~1.0 mm
2.2 m
Without gas only
Not applicable
Free cooling
EN60974-7