front of the grille. Secure the con-
nection plate using the screws.
2.
If required, connect the hose to the
dry air outlet and secure.
AD 400: Dry air outlet on the front
(DN 100 mm).
3.
Position the end of the hose at the
place of use.
Electrical connection
Procedure
1.
Make sure that the supply voltage
is the same as the connection volt-
age in the technical data.
2.
Provide an adequate fuse for the
socket and the power supply.
3.
Install an earth leakage circuit
breaker in damp rooms and build-
ing sites.
4.
Make sure that the mains plug is
suitable for the socket of the build-
ing.
5.
Make sure that the socket used is
earthed.
6.
Plug the mains plug into the socket.
11 Operation
WARNING! Negative effects caused
by negative pressure.
1
Make sure that no particles or
smoke, gas or similar may be
drawn in.
Make sure that the negative pres-
sure created has no negative effect
on safety or on the unit.
CAUTION! Risk of burns due to hot
regeneration air.
Do not reach into the regeneration
air.
Make sure there is a hose/air duct
attached to the regeneration air
outlet.
AD 200/300: Dehumidifying the
room
ATTENTION! Damage to the device!
When using the device in combina-
tion with a side channel
blower/noise box: Always put the
humidity switch to the 'I' position.
NOTE: The AD 200 must stand upright
and may not be tilted, otherwise it does
not function properly.
Procedure
1.
Make sure that the regeneration air
is directed out of the room via a
hose.
Set on/off button to "I".
2.
Turn the humidity switch from "0" to
3.
"I". Set the desired humidity, e.g.
20%, at the humidity switch. The
device will only start if the actual
room humidity is higher than the
target room humidity.
The dehumidifier will start operating. The
adsorption-dehumidifier runs until the
target room humidity has been reached,
then it will stop running. If the humidity
switch is at "I", the adsorption-dehumidi-
fier will run continuously.
19