INSTAL L ATION OF T HE AP PLI ANCE
1. Move the air conditioner with installed heat pipe and fittings in front of the window, and
the distance between the body and walls or other objects shall be of at least 50 cm.
2. Elongate the exhaust pipe and snap the flat end of the exhaust pipe joints into the hole of
the window sealing plate assembly.
Important Notice: The length of the exhaust hose shall be between 280 and 1,500mm, and
this length is based on the specifications of the air conditioner. Do not use extension tubes
or replace it with other different hoses, or this may cause a malfunction. Exhaust host must
be not blocked; otherwise it may cause overheating.
M A NUAL DR AI NAGE
• When the air conditioner stops after the water tank is full, turn off the machine power and
unplug the power plug.
Notes: Please move the appliance carefully, so as not to spill the water in the water tank at
the bottom of the body.
• Place the water container below the side water outlet behind the body.
• Unscrew the drainage cover and unplug the water plug, the water will automatically flow
into the water container.
Notes: Keep the drainage cover and the water plug properly.
E NGL I SH
12
50 cm
DRAINAGE INSTRUCTIONS
50 cm