EXHAUST HOSE KIT INSTALLATION
• Connect exhaust hose kit to the back of the unit and place the unit near the window.
Extend the flexible tube just enough to reach the outdoor, passing under the window
shutters set ajar.
• In case there is a window sill towards the inside of the room, it might be better to use the supplied
outlet nozzle. Insert the nozzle into the free end of the flexible tube
• Open the window and lock one of the shutters. Place the outlet nozzle between the two shutters
• Avoid sharp bends or plies of the flexible tube.
EXHAUST HOSE KIT
F l e x. T u b e / n o z z le
E xh a us t n ozz l e
co n n e c t o r
CARE AND CLEANING
WARNING! For safety's sake, be sure to turn the air conditioner OFF and also
disconnect it from the power supply before cleaning it.
1. Cleaning of the Air Filters
The air filters must be checked at least once every two weeks operation.
Operation with a dirty filter always causes a lower efficiency of the air condi-
tioner and severe product dama
side of the unit. Use a vacuum cleaner to remove light dust. If there is sticky
dust on the filter, wash it with lukewarm soapy water, then rinse in clean,
cold water and dry it before reinstallation.
2. Cleaning of Casing and Grille
To clean the air conditioner, wipe it with a clean soft cloth, lightly moisted. In
case it is stained, moisten the cloth with soapy water. Never use solvents or
harsh chemicals, nor very hot water. Do not pour water over the air condi-
tioner to clean it: this will damage the internal components and cause an
electric shock hazard.
3. Storage
If you are not going to make use of the air conditioner for a long period,
before storing it away clean the air filter. Always store the unit in the vertical
position. Do not put heavy objects on top of the unit and protect it with a
cloth or a plastic bag.
4. Transport
Preferably keep the air conditioner in the vertical position during transporta-
tion. If this is not possible, then lay it on one side; when at destination put
the air conditioner back in the vertical position and wait at least 4 hours
before using it for cooling.
5. For your safety care check periodically the conditions of the electric
supply cable; in case you should notice any damage due to usage, call
the nearest After Sale Service to get the cable replaced.