USEFUL ADVICE
If your air conditioner doesn't work properly, before requesting service, verify that:
-
the plug is properly inserted into the power socket; batteries in the remote control are not exhausted.
-
the circuit breaker is in the ON position and fuses have not blown, otherwise wait for 3 minutes and then start again;
EG
-
the air filter is not clogged, otherwise please clean it;
-
the flexible tube is correctly positioned without any sharp bends nor plies;
-
difference between room temperature and set temperature is over 1°C, otherwise please low the set temperature;
-
you have correctly carried-out the instructions contained in this manual.
CONDENSATE DRAINAGE
Water outlet drain (in Cooling mode, only with very high humidity in the air)
DRAINING EXCESS WATER
When the air conditioner works in cooling mode, it doesn't need
condensate draining, as condensate in usually vaporized, except for
special conditions of very high humidity levels.
In these cases it may be necessary to set continuous drainage (A
to drain. Replace the rubber plug onto
outlet) or empty the internal water container (A outlet). When the
internal water container is full the warning lamp on the display lights.
The unit will switch off automatically.
To empty the water container do the following action: put a container
under the drain pipe as the bottom rear of the unit and remove the
stopper and the rubber plug to allow the water container to drain.
Replace the rubber plug onto the drainpipe and continue to use.
Every time you move the unit to another room or when you store it,
discharge the condensate water container, through the drain pipe (A).
ATTENTION
The blinking of FULL BUCKET lamp, together with the stop of the air conditioner indicate that the condensate water tank is full.
F-GAS REGULATION (EC) no. 842/2006
Do not vent R410A into atmosphere: R410A is a fluorinated greenhouse gas, covered by Kyoto Protocol, with a Global
Warming Potential (GWP) = 1975.
Water outlet drain
(dehumidifying only mode)
B
A
humidif
n the air conditioner works in
When the air conditioner works in
ying mode, we suggest to set up
dehumidifying mode, we suggest to set up
order
o
drainage of condensate i
the continuous drainage of condensate in
dehumidif
obtain the maximum
order to obtain the maximum
ication efficiency.
dehumidification efficiency.
To make
conditioners
continuous drainage when the
1
To make continuous drainage when the air
mode sw
works in DEHUMIDIFYING
conditioners works in DEHUMIDIFYING
main
itch off the unit and remove the
mode switch off the unit and remove the
from the supply.
main plug from the supply.
(1)
Re
(1) Remove the plastic ring and the rubber
plug
ve the stopper and the rubber
plug from the drainpipe at the bottom
rear
rear of the air conditioner
(2) Connect a drain tube (25 mm inmer
(2)
diameter) on to the drain pipe : place
t a drain tube (25 mm inmer
the other end in a normal drain (2).
the
2
Make sure that the tube is free from
ter) on to the drain pipe : Plac
Make
other end in a normal drain (2).
twists and bends. The tube must
twis
decline over its entire length.
sure that the tube is free from
decline
ts and bends. The tube must
over its entire length.
n
air
rainpipe at the botto
m
onditioner
e
ontinuous
de
7
t