REPLACING OTHER WORN PARTS
Inspect the wear guard periodically. Have
a worn wear guard replaced by EGO
Customer Service as soon as the gear
case becomes visible (Fig. 18).
Have a worn debris flap or guide wheel
replaced by EGO Customer Service.
TRANSMISSION GEARS
LUBRICATION
The transmission gears in the cutting
head and power head assemblies need be
lubricated periodically with gear grease.
Add gear case grease after about every
50 hours of operation by removing the
sealing bolts (Fig. 19a & 19b).
Do not completely fill the transmission
gear case.
1. Stop the motor and remove the
battery pack.
2. Depending on which bolt you are
removing, lay the edger on its back
or hold it on its side so that the
sealing bolt to be removed is facing
upwards.
3. Use a 4 mm hex key (not included)
to loosen and remove the sealing in Fig. 19a & 19b.
4. Use a grease syringe (not included) to inject some grease into the bolt hole; do
not exceed 3/4 capacity.
5. Tighten the sealing bolt(s) after injection.