measured performance (CCA or A) with SoC
n
and T correction applied
measured performance (CCA or A) without
n
SoC and T correction
battery internal resistance in milliohms
n
(AA500p only)
battery conductance in siemens (AA500p
n
only)
The recommendation prompts (warning,
pass, fail) are determined using the SoC and
T corrected performance value only.
Interpreting Battery Life Test Results
End of Life (AA350, AA400, AA500p)
The battery has reached 'end of life' when
n
its measured performance has dropped
to 75% of the manufacturers specified
reference value. When this occurs, the
Battery Life = 0%, and the replace battery
indicator will turn on and the unit will
beep three times. Immediate battery
replacement is advised.
i
Depending upon the application, a battery
that has 0% battery life (based on the
manufacturers specification) may still have
enough capability to remain in service for a
period of time. For cranking batteries, the
subsequent 'Cranking performance Test'
EN
will provide a more direct indication of a
battery's ability to remain in service.
i
Battery Life can be calculated using an
end of life value other than 75%. BL =
(Cm-(Cr*Cu%))/Cr*(1-Cu%). Where Cm =
measured value, Cr = reference value, Cu%
= target end of life value.
~
Low Battery Life
(AA350, AA400, AA500p)
If Battery Life is between 0% and 50%,
n
the Low Battery Life indication,
(alternating pass / fail symbol) will turn on.
If the battery is used in an application
n
sensitive to downtime – the battery should
now be replaced proactively.
8
If the battery is not in a downtime
n
sensitive application, the battery can
remain in service, but should be tested
frequently. Replacing the battery soon is
recommended.
Good battery (AA350, AA400, AA500p)
If Battery Life is above 50%, the
n
will turn on. The battery can continue to
be used.
+
If the Battery Life is above 50%, but the
n
State of Charge is below 75%, the
and the
good and should be charged before using.
A more accurate Battery Life result will be
n
determined if the battery is charged and
tested again.
If the battery has been recently charged
n
and the
battery may not be able to accept a full
charge. Use the battery life value calculated
without SoC and T correction. Alternatively,
test the battery again while connected to a
charger.
Charge and Test Again
If the State of Charge was below 25%
n
at the start of the test a Battery Life
calculation is not performed, and a pass /
fail result will not be shown. The battery
must be charged and tested again.
i
If a reference value was not entered during
set up, Battery Life values will not appear
on the display, and Battery pass / fail results
will not be indicated.
i
If SoC is 25% or less, Battery Life values
~
will not appear on the display, and pass /
Fail results will not be indicated. The battery
must be charged and tested again.
Good battery, charge before using
(AA350, AA400, AA500p)
icon will turn on. The battery is
and
icons are displayed, the
icon
icon