Descargar Imprimir esta página

Grohe Essence Foot Control 30 311 Serie Instrucciones De Instalación página 8

Ocultar thumbs Ver también para Essence Foot Control 30 311 Serie:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 13
GB
Safety notes
• Installation is only possible in frost-free rooms.
• The plug-in connectors must not be directly or indirectly
sprayed with water when cleaning.
Application
Can be used in conjunction with:
• Pressurised storage heaters
• Thermally/hydraulically controlled instantaneous water heaters
Operation with unpressurised storage heaters (displacement
water heaters) is not possible.
• The GROHE Foot control function for switching the water
flow on or off is based on the principle of electrical charge
shifting on metallic surfaces. If the solenoid valve is closed
during Foot control sensing it will be opened, and if the
solenoid valve is already open it will be closed.
Specifications
• Flow pressure:
- min.
- recommended
• Operating pressure
• Test pressure
A pressure reducing valve must be fitted in the supply line if
static pressures exceed 0.5 MPa to satisfy noise level ratings.
Avoid major pressure differences between cold and hot water
supply!
• Flow rate at 0.3 MPa flow pressure
- Shower spray:
- Mousseur:
• Temperature hot water inlet:
Recommended (energy saving):
• Thermal desinfection possible
• Ambient temperature:
• Relative humidity:
• Voltage supply:
6 V lithium battery (type CR-P2)
• Rated power:
• Automatic safety shut-off after Foot control:
• Three water pulses indicate that a battery change is
necessary.
• Type of protection control:
• Water connection
Approval and conformity
This product conforms to the requirements of the
relevant EU guidelines.
The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
Installation
Refer to fold-out page I for hose lengths and installation
dimensions.
Caution: The control should be easily accessible.
Flush pipes thoroughly before and after installation
(observe EN 806).
Install the fitting, see fold-out page I, Figs. [1] to [7].
3
Connecting the faucet
Install bracket with control and connect, see fold-out page I
and II, Figs. [8] to [15].
Install weight on shower hose, see Fig. [16].
The sensor plate must be mounted on plastic or wooden
surfaces. The distance to metal surfaces must be taken into
account, see Fig. [9].
Important note
To ensure proper functioning when using metal sinks,
the sink must be connected to the control via the pre-
assembled yellow hose for potential equalisation,
see Fig. [17].
For all other sinks the yellow hose must be connected to
another suitable metal part for potential equalisation.
Country specific and local regulations must be
observed.
Putting into service
To prevent the risk of scalding, the outlet
temperature of the mixer unit should be set to
0.05 MPa
lukewarm.
0.1 - 0.5 MPa
Recommended maximum temperature: 38 °C,
max. 1.0 MPa
see Fig. [19].
1.6 MPa
The spout must always be positioned above the
sink to prevent water damage.
Ensure free runoff.
Insert battery, see fold-out page II, Figs. [18] - [21].
The sequence is important and must be observed.
The electronics will detect ambient conditions. During this time
approx. 9 l/min
the control indicator lamp flashes. The fitting must not be
approx. 11 l/min
activated (for approx. 1 min.).
max. 70 °C
Check connections for watertightness.
60 °C
Check for proper function, see Fig. [22].
4 - 40 °C
Adjusting of Foot control parameters to ambient conditions,
max. 80%
see fold-out page III, Fig. [23].
1.4 W
- The release varies depending on ambient temperature
60 s
and air humidity.
- Foot control parameters: 5 highest value... 1 lowest value...
- A value that is too high leads to the risk of continuous
IP 44
operation.
cold - right
The menu is started by pressing the button at the control unit
hot - left
for at least 10 seconds.
• The indicator lamp flashes once.
• The last stored value will then be displayed by flashing,
e.g. three times for level 3 (factory setting).
• Each time the button is pressed the value goes up one level.
• The selected level is indicated by the number of flashes.
- If no further buttons are pressed, the indicator lamp signals
the last set value 2 more times. The lamp then emits a
continuous signal and the menu is exited. The last stored
value will be saved.
Operation, see fold-out page III, Figs. [24] to [27].
If the flow rate in the Foot control function is too high,
exchange non-return valve 08 565 with 64 689, see fold-out
page II, Fig. [36] and fold-out page IV.
Shower jet diverter see Fig. [27].
Flow rate limitation, see Fig. [28] and [29].

Publicidad

loading

Este manual también es adecuado para:

Essence foot control 30311000