POWER Regulator:
The output energy can be set between 50% and 100% of maximum energy with the POWER regulator. The
LEDs of the fence voltage display show the currently set value during the setting. For example, one lit LED in-
dicates an output energy of 50%, 3 lit LEDs an output energy of 70% and 6 lit LEDs an output energy of 100%.
After 2 seconds this display is extinguished and the last output energy set is adopted.
5. Maintenance
Table 13 (12V rechargeable battery)
Flashing light
green
Flashing light
red/green
Flashing light
red
The rechargeable battery must be recharged at the latest when discharged down to 80% (only 20% remaining capacity left)
to prevent a flat battery. The rechargeable battery indicator (LED2) lights up:
Do note that temperature and measurement deviation may cause these figures to vary.
Caution!
When using a solar system
Only carry out a battery or rechargeable battery test at start of the day ( no solar power supplied - cover panel )
6. Disassembly, Dismantling, Storage and Transport
Disassembly, Dismantling
Before starting disassembly:
●Switch off energizer
●Disconnect entire energy supply from the energizer.
●Remove operating/auxiliary materials and any remaining working materials and dispose of in an environmen-
tally-compatible manner.
Then properly clean sub-assemblies and parts and disassemble them in taking account of the local industrial
safety & environmental protection provisions in force.
Storage, Transport
Ensure that the energizer is both stored and transported only when switched off.
NOTE!
Ensure that rechargeable batteries are stored in ventilated and dry rooms.
7. Faults and Repairs
WARNING!
Repairs may only be carried out by qualified persons.
Only the spare parts prescribed by the manufacturer may be used.
Subject to technical alterations!
ranger AN2000, ranger AN3000, ranger AN4800
Remaining capacity
40-100 %
20-40 %
0-20 %
Rechargeable battery good
Charge the battery
Rechargeable battery absolute-
ly depleted
7