MAINTENANCE INSTRUCTIONS
Maintenance instructions:
If dryer does not operate, check the following:
@ Clean lint screen after each cycle.
@ Electric supply is connected.
@ Removing accumulated lint:
@ Circuit breaker is not tripped or fuse is not blown.
« From inside the dryer cabinet:
@ Door is closed. Listen closely to hear door switches activate.
Lint should be removed every 2 years or more often,
@ Selected cycle button has been pressed firmly and display
depending on dryer usage. Cleaning should be done
shows cycle time.
by a qualified person.
@ Check that gas supply shutoff valves are set in open position.
* From the exhaust vent:
Lint should be removed every 2 years, or more often,
if you need assistance:
depending on dryer usage.
Contact your authorized Maytag Commercial Laundry distributor
or visit: www.MaytagCommercialLaundry.com. When you call,
you will need the dryer model number and serial number.
Both numbers can be found on the serial-rating plate located
on your appliance.
TECHNICAL SPECIFICATIONS - GAS DRYER
220-240V~50Hz 1ph 3A max. IP24 Clothes capacity: 9.0 kg max.
Factory set for NATURAL GAS: Injector size: 2.2 mm_
Heat input gross: 5.9 kW
European Country:
CH, CZ, CY, ES, GB, GR, HR,
CY, CZ, DK, EE, Fl, GR, HU, IT,
IE, 1T, PT, SI, SK, TR
NO, RO, SE, SK, TR
European Gas Category:
Hopa,
llouap/p
Gas Flow Rate:
0.562703 m°/hr
0.562703 m°/nr
Supply Pressure (G20):
20 mbar
20 mbar
Factory Adjusted Pressure:
7.4 mbar
7.4 mbar
With LP Gas Conversion Kit: Injector size: 1.25 mm _ Heat input gross: 6.4 kW
European Country:
CH, CZ, CY, ES, GB, GR, HR,
CY, CZ, DK, EE, Fi, GR, HU, IT,
IE, IT, PT, SI, SK, TR
NO, RO, SE, SK, TR
European Gas Category:
lloya4
lloy3B/P
Butane Supply Pressure (G30):
28-30 mbar
30 mbar
Adjusted Pressure:
N/A
N/A
Propane Supply Pressure (G31):
37 mbar
30 mbar
Adjusted Pressure:
N/A
N/A
With France/Belgium NATURAL GAS conversion kit: Injector size: 1.65 mm _ Heat input gross: 5.9 kW
European Country:
FR, BE
European Gas Category:
loc
Supply Pressure (G20):
20 mbar
Supply Pressure (G25):
25 mbar
Adjusted Pressure:
N/A
NOTE: Conversion kit : From Natural Gas to LP Gas : Whirlpool Part No. W10233219.
Conversion kit : From Natural Gas to Natural Gas - France/Belgium: Whirlpool Part No. W10184947.
Manufacturer : Whirlpool Corporation, Benton Harbor, Michigan 49022, USA.
10

Publicidad

loading

Este manual también es adecuado para:

Mdg22pd