SPECIFICATIONS
Cat. No. ..................................................... 2876-20
Volts.............................................................. 18 DC
Battery Type .................................................M18™
Charger Type................................................M18™
Force .......................................................... 11 Tons
Capacity..................................#4-1000 MCM Cu/Al
Module/FCC ID ............................ BGM11S/QOQ11
Weight ...........................................................14 lbs
Weight ...........................................................16 lbs
(With heaviest compatible battery pack)
Recommended Ambient
Operating Temperature ......................0°F to 125°F
FUNCTIONAL DESCRIPTION
2
4
3
1
13
12
11
1. Nest
2. Crimping clevis
3. Worklight LED's
4. LED indicator
5. Electronic reverse
trigger
6. Manual release button
ASSEMBLY
Recharge only with the charger
WARNING
specified for the battery. For spe-
cific charging instructions, read the operator's
manual supplied with your charger and battery.
Removing/Inserting the Battery
To remove the battery, push in the release buttons
and pull the battery pack away from the tool.
Always remove the battery pack
WARNING
any time the tool is not in use.
To insert the battery, slide the pack into the body
of the tool. Make sure it latches securely into place.
Only use accessories specifically
WARNING
recommended for this tool. Others
may be hazardous.
To avoid damage to the tool, do not
CAUTION
operate the tool without the nest
fully latched.
An incomplete or faulty crimp could
WARNING
cause a fire. Use tool only with
connectors for which they are rated. Tool and
connectors must be used in an approved com-
bination to achieve a successful operation. Im-
proper combinations can result in a faulty crimp.
Electric shock, fire, explosion, and property
damage could occur.
ONE-KEY™
To learn more about the ONE-KEY™ functionality
for this tool, go to milwaukeetool.com/One-Key. To
download the ONE-KEY™ app, visit the App Store
or Google Play™ from your smart device.
(Tool-Only)
5
6
018536_2876
9
10
7. Hanger
8. ONE-KEY™ indicator
9. Handle
018580_2878
10. Trigger
11. Nest release lever
12. Indenter
13. Nest lock pin
Solid Blue
Blinking Blue Tool is actively communicating with
Blinking Red Tool is in security lockout and can
WARNING
damage, work on deenergized lines when
possible. Tool is not insulated. Should work
on energized lines be required, ensure all proper
7
precautions, including those contained in NFPA
70E, have been taken first.
Keep hands away from crimping jaws while
tool is in use. Fingers could be crushed.
Always wear proper eye protection marked to
comply with ANSI Z87.1.
8
Before crimping:
• Inspect the crimping ram, nest and clevis for cracks
or other damage. Do not use damaged parts. Con-
tact a MILWAUKEE service facility.
• Ensure the nest is properly latched.
• Connectors and cables must be used in an AP-
PROVED COMBINATION. Improper combinations
can result in a faulty crimp.
• Inspect and discard workpieces with cracks or wear
before use. Materials may crack or shatter.
• Follow installation specifications as specified in Table
A and ANSI Table using an Approved Combination of
connectors and cables as indicated. Other uses may
cause damage to the tool and workpiece.
1. Insert battery pack.
2. Place the ram and nest around the connector.
3. Hold tool securely. Press and hold the trigger.
4. When the cycle is complete the tool will auto
retract and the indicator will light. Release the
trigger.
LED
Indicator
Solid Green Tool completed the operation and
Solid Red
Flashing Red Tool did NOT complete the operation.
Flashing
Red/Green
(after Solid
Green or
Solid Red)
®
6
ONE-KEY™ Indicator
Wireless mode is active and
ready to be configured via the
ONE-KEY™ app.
the ONE-KEY™ app.
be unlocked by the owner via the
ONE-KEY™ app.
OPERATION
To reduce the risk of arc flash,
electric shock and property
Crimping
Definition
reached full crimping pressure.
Tool completed the operation but did NOT
reach full crimping pressure.
Tool has reached its service interval. Red/
Green flashing will begin after the solid
Red or Green indicator for the operation
MILWAUKEE
is displayed.
that the tool be inspected and preventative
maintenance completed. Return tool to a
MILWAUKEE service facility.
recommends