ENGLISH
(Original instructions)
Specifications
Compatible models
Dust collection capacity
Weight
* As a rough guide, a cleaner with; max air flow 1.3 m
suction 2.5 kPa or higer is suitable for this attachment. Check the Makita product
catalog for compatible models.
About the cyclone attachment
Using the cleaner with the cyclone attachment installed reduces the amount of dust that
enters the dust bag or paper dust pack, which helps to prevent the suction force from
weakening. In addition, cleaning after use is also simple.
Operating precautions
Be sure to thoroughly read and understand this instruction manual and the instruction
manual of the cordless cleaner to which the cyclone attachment will be installed before
use. Keep this instruction manual in a safe place for quick access whenever needed.
Always make sure that the cleaner unit is switched off and the battery cartridge
is removed before installing or removing the cyclone attachment.
• If the battery cartridge is left inserted, the cleaner may start unexpectedly and result in injury.
Clean the mesh filter of the cyclone attachment and the dust bag of the cleaner
unit when they become clogged.
• Continued use in the clogged condition may result in heating or smoke.
Installing the cyclone attachment
• Install the cyclone attachment and straight pipe by inserting firmly while twisting so
that the parts do not come loose during use.
• When using the cyclone attachment with a capsule type cleaner, the capsule may come
loose if twisted in the direction opposite of the arrows in the figure below.
• When the cyclone attachment is attached, do not use the cleaner in the horizontal or
upward facing condition .
• Doing so may cause the mesh filter to become clogged.
Fig. 1: 1. Straight pipe 2. Cyclone attachment 3. Cleaner
1. Install the cyclone attachment to the suction inlet of the cleaner.
2. Use this attachment with the straight pipe installed.
Makita cordless cleaners*
400 mL (0.11 gal.)
0.35 kg (0.77 lbs)
3
CAUTION
CAUTION
4