Descargar Imprimir esta página

Lynx LM24BFL Manual De Instrucciones página 15

Publicidad

Idiomas disponibles

Idiomas disponibles

USING YOUR BEER DISPENSER
CO
Regulator (Single Dispense Tower)
2
Your beer dispenser comes equipped with a 5 pound CO
tank and a single gauge regulator. The gauge reads the
pressure being supplied to the beer keg. Follow the proce-
dure below to adjust the pressure to 12 - 14 psi (0.8 to 1
bar) for lager beer or 9 - 12 psi (0.6 to 0.8 bar) for ale's.
To adjust the pressure (Single Gauge):
1. Close the shutoff valve at the bottom of the regulator.
2. Be sure the faucet handle is closed on the tower (see
Figure 30).
3. Loosen the lock nut by turning ↶ counterclockwise us-
ing the
" open end wrench until loose, this will allow
1
2
adjustment of the pressure adjustment screw.
4. With the flat bladed screwdriver turn the adjustment
screw ↷ clockwise to increase the pressure or ↶ coun-
terclockwise to decrease the pressure.
5. Open the shutoff valve on the bottom of the regula-
tor. The gauge reading may drop but will return very
quickly.
6. Pull the ring on the keg coupler to allow the gas to flow
momentarily.
7. Make any fine adjustments if necessary with the adjust-
ment screw.
8. Tighten the locknut with the
turning clockwise ↷.
Pressure Gauge
Pressure
Adjustment
Lock Nut
Screw
Figure 33
(Regulator for Single
Dispense Tower)
All manuals and user guides at all-guides.com
2
" open end wrench by
1
2
Ring on
keg
coupler
Figure 32
shutoff valve
(closed posi-
tion shown)
CO
Regulator (Double Dispense Tower)
2
Your beer dispenser comes equipped with a 5 pound CO
tank and a dual gauge regulator. The lower gauge should
be reading approximately 750 psi (52 bar) when the tank is
properly filled and the tank is not in the refrigerator (at room
temperature). The tank will read less when chilled. Use this
lower gauge as an indicator of how much CO � you have left
in the tank.
The upper gauge reads the pressure being supplied to the
beer keg. Follow the procedure below to adjust the pres-
sure to 12 - 14 psi (0.8 to 1 bar) for lager beer or 9 - 12 psi
(0.6 to 0.8 bar) for ale's.
To adjust the pressure (Upper Gauge):
1. Close the shutoff valves at the bottom of the regulator.
2. Be sure the faucet handle is closed on the tower (see
Figure 30).
3. Loosen the lock nut by turning counterclockwise us-
ing the
" open end wrench until loose, this will allow
1
2
adjustment of the pressure adjustment screw.
4. With the flat bladed screwdriver turn the adjustment
screw clockwise to increase the pressure or counter-
clockwise to decrease the pressure.
5. Open the shutoff valve on the bottom of the regula-
tor. The gauge reading may drop but will return very
quickly.
6. Pull the ring on the keg coupler to allow the gas to flow
momentarily.
7. Make any fine adjustments if necessary with the adjust-
ment screw.
8. Tighten the locknut with the
turning clockwise.
Pressure
Adjustment
Screw
Lock Nut
(2) shutoff
valves (closed
position shown)
Figure 34
(Regulator for Double
Dispense Tower)
CARE AND USE/INSTALLATION
2
" open end wrench by
1
2
Upper Gauge
Lower Gauge
15

Publicidad

loading

Este manual también es adecuado para:

Lm24bf