English
Installation and operating instructions
PDC – Pulse Data Capture Modul
1. General information
The PDC module (Pulse Data Capture) is used to
integrate meters with a pulse output in radio
systems or smart metering systems. The PDC is also
referred to as a wireless M-Bus or LoRaWAN®
converter. It processes pulse signals generated by
the meter, converts the information into radio
signals and transmits the radio telegrams to
suitable receivers or receiving systems. With the PDC
module, conventional meters with a pulse interface
can be upgraded to wireless meters. The module is
mainly used in the field of energy management and
consumption recording. Users are usually utility
companies and service providers in the areas of
consumption recording, billing, energy monitoring,
etc. Operational safety is only guaranteed if the
device is used as intended, according to the
manufacturer. No liability is accepted for damage
caused by other uses. Any modification is only
permitted with the approval of the manufacturer.
Otherwise the manufacturer's declaration will
become void.
1.2. Safety instructions
Attention! The device is only intended for the
■
designated use.
Attention! Improper use may result in damage to
the device.
Caution! Improper opening of the device can
lead to damage and possibly injury to hands.
The device is filled with resin at the factory and
is not designed to be opened.
Caution! Unauthorized work on the device can
■
no longer guarantee its safety and functionality.
Caution! Loss of functionality and injuries may
result from unauthorized work on the device.
Make sure of the required procedure in advance.
Caution! Make sure that the installation envi-
■
ronment corresponds to the specified operating
range. Adhere to specified temperature and
limit values at all times.
Caution! To avoid damaging the device or impai-
■
ring its functionality, chemical cleaning agents
should not be used. If cleaning is necessary, use
a dry or slightly damp cloth.
Notice! The device is equipped with a perma-
■
nently installed lithium battery, which must not
be recharged. This type of battery is classified
as dangerous goods (Hazardous goods class 9).
The applicable transport regulations must be
observed! Data sheets, safety data sheets and
test reports of the batteries are available on
request. Please also note the following general
information on handling batteries.
Warning! The instrument contains a
■
non-rechargeable lithium battery. Attempting to
recharge it will damage the device and possibly
cause injury.
Attention! Under no circumstances may the
■
device be disposed of in normal household
waste. Please observe our regulations for
disposal mentioned separately in this manual.
General information on handling lithium batteries
or devices with lithium batteries:
Caution! The following must be observed when
handling lithium batteries and devices with lithium
batteries.
store protected from moisture
■
do not heat or throw into fire to avoid explosions
■
do not short-circuit
■
do not open or damage
■
do not recharge
■
do not store within reach of children
■
1.3. Typical applications:
Wireless remote readout of water meters with
■
walk-by or drive-by system
Radio transmission of the readings to mobile or
■
stationary receivers
By the means of the PDC module conventional
meters with pulse output can be integrated in radio
or M-Bus systems in an easy and cost-efficient way.
For this purpose, the pulse output of the meter
is to be connected with the battery powered PDC
module.
7