Hazet-Werk 7000 sTAC Serie Instrucciones De Uso página 32

Llave dinamométrica / medidora de ángulos de giro electrónica
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 67
1 . Faults:
Message
The 4th signal level with per-
manent red light, permanent
acoustic signal and permanent
vibration is activated.
"Overload error" appears.
Code 0000
Memory full – data will be lost
beginning from next measu-
rement!
In conjunction with yellow light
signal.
Batteries flat
The rotation angle measure-
ment / display does not conti-
nue to increase during operati-
on and/or drops briefly.
The rotation angle is not mea-
sured and/or displayed.
32
Faults
Reason
The torque applied was above the maximum
permitted torque range of the torque wrench
with built-in angle gauge.
Access to the menu is blocked by a code.
All memory slots are full.
The rechargeable battery is discharged.
The snug torque was exceeded at the start
of the thread and/or operation, which activa-
ted the rotation angle measurement. Further
rotation will bring the torque below the previ-
ously reached snug torque. This can happen
if the thread is damaged or soiled.
The screw is already so firmly tightened that
it will no longer rotate. This can happen if the
screw has been inserted, for example, with
an impact wrench.
Action
If the fourth signal level is reached, the screw action
must be aborted immediately. Failure to comply with
these instructions can result in (irreparable) damage to
the torque wrench with built-in angle gauge. Confirm
the message by pressing
Switch the torque wrench with built-in angle gauge off
by pressing
and on again by pressing
Enter the code to enable access to the menu.
The factory set code is "0000".
If you lose your code, please contact your HAZET
partner quoting the serial number of the torque wrench
with built-in angle gauge.
Confirm the message by pressing
taneously.
You are able to access the data in the memory or save
it externally. If you continue to work, the first block with
memory slots is deleted.
Stop using the torque wrench with built-in angle
gauge. Replace or charge the rechargeable battery.
See Section 7, "Commissioning"
Proceed in line with the instructions for this screw-joint:
e.g. undo the screw and re-tighten it, or replace it with
a new one. If necessary, clean and/or re-cut the thread.
Proceed in line with the instructions for this screw-joint:
e.g. undo the screw and re-tighten it, or replace it with
a new one.
and
at the same time.
and
simul-

Publicidad