Note: Troubleshooting
problems may have similar causes and solutions.
PROBLEM
Low pressure or not
enough air
or
Compressor does not
stop
Air leaks from regulator,
or regulator does not
regulate pressure
Regulated
pressure
gauge reading drops
when air accessory
is
being used
Pressure relief valve
opens
Motor will not run
Air leaking through
bleeder valve after
compressor shuts off
POSSIBLE CAUSE
SOLUTION
Tank petcock is open
Close petcock.
Check fittings with soapy water. Tighten or reseal leaking fittings. DO
Fittings Leak
NOT OVERTIGHTEN.
Restricted air intake
Clean or replace intake filter element.
Prolonged excessive use of air
Decrease amount of air used.
Check air requirement of accessory.
If it is higher than CFM and
Compressor
not large enough
)ressure supplied by compressor, you need a larger compressor. Most
accessories
are rated at a 25% duty cycle.
Hole in air hose
Check and replace if necessary.
Tank leaks
_, _
Immediately replace tank. DO NOT attempt to repair.
Blown seals
Contact a Sears or other qualified service center.
Valve leaks
Contact a Sears or other qualified service center.
Leaking or worn piston
Contact a Sears or other qualified service center.
Dirty or damaged regulator
Contact a Sears or other qualified service center.
internal parts.
This is normal
If pressure drops too low, adjust regulator while accessory is used.
Check air requirement of accessory.
If it is higher than CFM and
Compressor
not large enough
)ressure supplied by compressor, you need a larger compressor. Most
accessories
are rated at a 25% duty cycle.
Tank pressure exceeded normal
Contact a Sears or other qualified service center.
operating pressure
Pressure switch stuck
Contact a Sears or other qualified service center.
Tank pressure exceeds preset
Motor wilt start automatically when tank pressure drops below kick-in
)ressure switch limit
)ressure of pressure tank.
Motor overload protection has
Let motor cool off and overload switch will automatically reset. This
tripped
may take several minutes.
• Replace blown fuse or reset circuit breaker. Do not use fuse or circuit
breaker with higher rating than specified for your branch circuit.
Fuse blown or circuit breaker
• Check for proper fuse; "Fusetron" type T is acceptable.
tripped
• Check for tow voltage and proper extension cord size.
• Disconnect other applications from circuit. Operate compressor on a
dedicated circuit.
Dirty or defective check valve.
Replace or clean the check valve (see "To replace or clean check
valve" in the maintenance section).
Wrong wire gauge in cord or
Check for proper gauge and extension cord length.
excessive extension cord length
Loose electrical connections
Contact a Sears or other qualified service center.
Paint spray on internal motor
Contact a Sears or other qualified service center. Do not operate
)arts
compressor in the paint spray area
Possible defective motor
Contact a Sears or other qualified service center.
Dirty or defective check valve.
Replace or clean the check valve (see "To replace or clean check
valve" in the maintenance section).