Door latch inversion
Remove the door latch and the cover from the door. To remove the handle, unscrew it.
Reassemble them on the opposite side.
The procedure indicates the left-right inversion. Make the steps opposite to the
right-left opening.
7. DOOR PANEL REPLACEMENT
Is possible replace the fridge and drawer door panels by following the instructions below.
(Annex 6)
•
Remove the plastic base using a screwdriver
•
Remove one or both panels and replace them
•
To facilitate replacement, remove the door
The panel can also be replaced with one of a different thickness. The thickness can vary
from 0.8 to 3 mm.
8. ELECTRICAL CONNECTION
This installation and electrical connection must perform in accordance with the
regulations by a qualified technician. Connect the DC power supply to 12V or 24V
directly to the battery according to the following instructions.
Section (mm^2)
2.5
4
6
10
•
Cable size: Battery and electronics connection.
12 V cut-out V
10,4
Protect the DC power line with a suitable min. 20A circuit breaker. Provide a fuse close to
the positive battery pole and a 15A fuse for 12 VDC power supply and 7.5A for 24 VDC
power supply.
ENG
24
RESPECT THE POLARITY
Max line length 12V (m)
STANDARD BATTERY PROTECTION SETTINGS
12 V cut-in V
11,7
2.5
4
6
10
24 V cut-out V
22,8
Max line length 24V (m)
5
8
12
20
24 V cut-in V
24,2