Performance Data Sheet.
SmartWater Filtration System GX1S50R Using Filter GXRLQR
■ This System has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration of the indicated
substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system,
as specified in NSF/ANSI 42 and 53.
■ Actual performance may vary with local water conditions.
WARNING:
Do not use with water that is microbiologically unsafe or with water of unknown quality without adequate disinfection
before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
USEPA
Parameter
MCL
Chlorine taste and odor
Nominal Particulate**
USEPA
Parameter
MCL
Turbidity
0.5 NTU***
Cysts
99.95% red.
Asbestos
99% red.
Lead, pH 6.5
0.010 mg/L
Lead, pH 8.5
0.010 mg/L
Mercury, pH 6.5
0.002 mg/L
Mercury, pH 8.5
0.002 mg/L
Atrazine
0.003 mg/L
Lindane
0.0002 mg/L
*Tested using a flow rate of 0.78 gpm (2.95 l/min); pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 68° ± 5°F (20° ± 3°C)
**Measurement in particles/mL. Particles used were 0.5–1 microns.
***NTU—Nephelometric Turbidity Units
Operating Specifications
Capacity: certified for up to 750 gallons (2,838 l); up to six months
Pressure requirement: 35–120 psi (2.8–8.2 bar)
Temperature: 33–100°F (0.6–38°C)
Flow rate: 0.78 gpm (2.95 l/min)
Replacement Filter Canister/Estimated Replacement Costs
GXRLQR—Replacement filter canister $30–35
For replacement parts, call toll-free 800.626.2002 (U.S.),
800.663.6060 (Canada–English), 800.361.3869 (Canada–French)
4
Influent
Influent
Challenge Concentration
Average
2.0 mg/L +10%
2.00 mg/L
≥ 10,000 particles/mL
14,000,000 #/mL
Influent
Influent
Challenge Concentration
Average
11 + 1 NTU***
10.5 NTU
Min. 50,000L
122,500 #/L
10
7
and 10
8
fibers/L;
126.5 MF/L
fibers >10 μm long
0.015 mg/L + 10%
0.150 mg/L
0.015 mg/L + 10%
0.150 mg/L
0.006 mg/L ± 10%
0.006 mg/L
0.006 mg/L ± 10%
0.0059 mg/L
0.009 mg/L + 10%
0.0102 mg/L
0.002 mg/L + 10%
0.0019 mg/L
Standard No. 42: Aesthetic Effects
Effluent
Average
Maximum
0.050625 mg/L
0.06 mg/L
196,666 #/mL
370,000 #/mL
Standard No. 53: Health Effects
Effluent
Average
Maximum
0.125 NTU
0.30 NTU
<1
<.17
<0.001
<0.001
0.0003
0.00073
0.00105
0.000035
Trademark/Model Designation
GE SmartWater GX1S50R
GE SmartWater GXRLQ
Manufacturer: GE Appliances
The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section
116830 of the Health and Safety Code for the following health related contaminants:
Microbiological Contaminants and Turbidity
Cysts
Turbidity
Organic Contaminants
Atrazine
Lindane
Rated Service Capacity:
Do not use where water is microbiologically unsafe or with water of unknown quality, except that systems certified for
cyst reduction may be used on disinfected waters that may contain filterable cysts.
% Reduction
Average
97.52%
99.00%
% Reduction
Average
98.80%
<1
>99.99%
<.17
>99.99%
<0.001
>99.30%
<0.001
>99.30%
0.0005
95.00%
0.0018
88.10%
0.0027
89.40%
0.00016
97.90%
State of California
Department of Health Services
Water Treatment Device
Certificate Number
08 -
1952
Date Issued: December 15, 2008
750 gal
Min. Required
Minimum
Reduction
97.00%
>50%
97.40%
>85%
Min. Required
Minimum
Reduction
97.30%
0.5 NTU
>99.99%
>99.95%
>99.99%
>99%
>99.30%
0.010 mg/L
>99.30%
0.010 mg/L
91.70%
0.002 mg/L
69.20%
0.002 mg/L
76.30%
0.003 mg/L
91.80%
0.0002 mg/L
Replacement Elements
GXRLQR
GXRLQR
Inorganic/Radiological Contaminants
Asbestos
Lead
Mercury
0.78 gpm
Rated Service Flow: