SM(GZA)
5. Technical data
5.1. Technical data of the pump part SM (GZA)
Parameter
The temperature of the pumped water
Maximum working pressure
Maximum suction depth
Impeller type
Type of seal on the shaft
Outlet pipe
Inlet pipe
Impeller material
Material of the pumping part
5.2. Technical data of the SM (GZA) engine
Type
Poles
Insulation class
protection class
Type of work
Phase
shaft
Aluminum case
The manufacturer reserves the right to make structural changes to the product.
6. Permitted and prohibited conditions of use
WARNING! Failure to comply with the conditions of use of the pump described below will lead to a situation
of using the pump that is technically inappropriate and may put people at risk. In this case, neither the Seller
nor the Pump Manufacturer are liable for damage to people, objects and/or the pump. In this case, the
pump warranty is void.
6.1. Conditions of use are allowed
The pump is designed to work with water or other liquids compatible with stainless steel, in particular:
-
communal systems: for raising water, booster installations, air conditioning, irrigation;
-
withAgricultural: irrigation, pumping of KAS;
-
food industryIt is: pumping water, milk, beer wort and other similar liquids according to the
characteristics of water.
Use the pump in accordance with its technical characteristics, specified in section 5 of this manual.
6.2. Conditions of use are prohibited
Any use of the pump in conditions not specified in clause 6.1. is prohibited. It is also prohibited to use the pump for
pumping sea water, dirty water, explosive substances, pumping water at temperatures higher than specified in point
5.1., when working without water (dry water).
in -10
+ 110
10 bar
6 m (at 35
closed
mechanical
see catalog
see catalog
stainless steel
Power
see on the pump
with forced ventilation
2
F
IP55
continuous
see on the pump
stainless steel steel
Pumps SM(GZA)
C up to +80
C for NBR/Ceramic/Carbon to
°
°
C for Viton/Ceramic/Carbon
o
C)
°