13. TROUBLESHOOTING
ATTENTION! Repairs must only be performed by
specialized and qualified personnel. Any repair work
not performed by professional personnel may cause
damage to the appliance for which the manufacturer will
not be liable.
The following problems can be fixed by the consumer
without the assistance of the Service Department.
The drawer is not hot enough. Make sure that:
• The appliance is turned on;
• The correct temperature has been set;
• The opening of the ventilation fan is not blocked by
plates or other large obstructions;
• The drawers have had sufficient time to heat up.
The drawer is not hot at all. Make sure that:
• You hear the fan running;
• If the fan is turned on this means that the heating
system is working;
• If the fan does not work this means it is defective;
• The circuit fuse is blown.
14. APPLIANCE INSTALLATION
14.1 Before you begin installation
Make sure that the voltage shown on the appliance label
corresponds to that of your electrical system.
Open the drawer and remove all accessories and
packing materials.
Attention! The front of the drawer may be covered
with a protective coating over it. Carefully remove the
coating before using the appliance. Start by removing
the protective film from the bottom. Make sure that
the drawer is not damaged. Be certain that the drawer
closes properly. In case of damage, contact the Service
Department.
The warming drawer can only be attached and installed
with the tools provided by the appliance manufacturer.
The manufacturer does not guarantee the operation of
the appliance if materials from a different manufacturer
have been used. The manufacturer is not responsible for
damage caused by improper use.
14.2 Proceed
Before you begin assembling the drawers of the
appliance, make sure there is enough room to fit the
drawer and the appliance.
The precise dimensions for the installment are indicated
in mm. Follow these guidelines for assembly:
• Position the drawer so that it is directly centered
• Be certain that the frame is perfectly perpendicular
• Open the drawer and fix the structure to the wall with
the two screws already in place
14.3 Electrical Installation
The electrical connection must be made by a qualified
electrician conforming to current regulations.
Electrical connections
Before connecting the oven to the mains power supply,
make sure that: - The supply voltage corresponds
to the specifications on the data plate on the front of
the oven. - The mains supply has an efficient earth
(ground) connection complying with all applicable laws
and regulations. Correct earthing (grounding) is a legal
requirement. The power cable should never reach a
temperature 50° C above ambient temperature at any
point along its length. If a fixed appliance is not provided
with a power cable and plug, or some other device
permitting it to be disconnected from the mains electricity
supply, with a gap between the contacts big enough to
guarantee class III overvoltage protection, then such a
device must be fitted to the power supply in compliance
with the regulations governing electrical installations.
The socket or switch must be easily reachable with the
oven fully installed.
CABLE TYPES AND MINIMAL DIAMETERS
H05RR-F 3x0,75 mm²
H05VV-F 3x0,75 mm²
H05RN-F 3x0,75 mm²
H05V2V2-F 3x0,75 mm²
25
SASO
H05RR-F 3x1,5 mm²
H05VV-F 3x1,5 mm²
H05RN-F 3x1,5 mm²
H05V2V2-F 3x1,5 mm²
GB