Descargar Imprimir esta página

Magmaweld monoCUT 45ix Manual Del Usuario página 17

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 197
monoCUT 45ix / monoCUT 45i
• Make sure there is good metal-to-metal contact. Never connect the ground clamp to the falling part of the metal.
The power supply must be grounded in accordance with national and local electrical
regulations to ensure personal safety, reduce electromagnetic interference, and create
appropriate operating conditions.
• Magmaweld brand plasma cutting torches should be used
2.5.3 Torch Connections
according to the cutting method to be used with the power
source.
• A manual torch is used for manual cutting, and
a mechanized torch for mechanized cutting.
• For the torch connection, insert the torch connector into its
connector on the power supply and turn it to the right.
Make sure the connection is completed.
• Keep the power supply off while connecting the torch.
• See 5.1 for detailed information on torches.
2.6 Placing Consumables
• The materials used for manual and mechanized plasma cutting torches are different from each other.
• First, the consumables of the torch must be prepared.
• Appropriate consumables should be selected according to the torch type and method used.
• Consumables must be installed in the specified order.
Swirl Ring
Electrode
Nozzle
Retaining Cap
Shield
www.magmaweld.com