Piping Length and Elevation
Pipe Size
Capacity
GAS
(Btu/h)
mm
inch
9k, 12k Ø9.52
3/8
Indoor unit
CAUTION
!
Capacity is based on standard length and maximum allowable length is on the basis of relia-
bility.
Additional refrigerant must be charged for pipe length longer than 41ft(12.5m).
Operation ranges
The table below indicates the temperature ranges the air conditioner can be operated within.
Mode
Cooling
64.4°F~89.6°F(18°C~32°C)
Standard
LIQUID
Length
m(ft)
mm
inch
Ø6.35
1/4
7.5(25)
A
B
Outdoor unit
Indoor temperature
Max.
Min
Max.
Elevation
Length
Length
Ⓑ m(ft)
Ⓐ m(ft)
Ⓐ m(ft)
10(33)
2(6.6)
20(66)
A
Indoor unit
Outdoor temperature
-0.4°F~118.4°F(-18°C~48°C)
Additional Refrigerant for
longer than 12.5m(41ft)
g/m
oz/ft
20
0.22
Outdoor unit
B

Publicidad