suit the wall material. Always ask a specialist for the correct plug/screw combination indicating the maximum
load and the building material.
Procedure:
Step 1: The holes for the installation are on the product.
Step 2: Hold the product onto the location where it is to be installed.
Step 3: Mark the boreholes with a pen or a suitable tool.
Step 4: Drill the holes.
Step 5: Hold the product in the desired position and tighten it.
DMX-512 connection
The DMX-splitter can either be connected directly to the lighting controller or after a series of DMX-devices.
You can connect up to 31 DMX-devices to every DMX output socket..
If you connect the splitter after a DMX-device the number of DMX-devices before the splitter must not
exceed 31.
The wires must not come into contact with each other, otherwise
Only use a stereo shielded cable and 3-pin or 5-pinXLR-plugs and connectors in order to connect the
controller with the fixture or one fixture with another.
Occupation of the XLR-connection:
Caution: At the last fixture, the DMX-cable has to be terminated with a terminator. Solder a 120
between Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last fixture.
After you connected the device to the mains, the DMX Split 4 is ready for use.
Connection with the mains
Connect the device to the mains with the power plug.
The occupation of the connection cables is as follows:
the fixtures will not work at all, or will not work properly.
13/24
Ω
resistor
00026253.DOC, Version 1.1