Float Voltage
Restart Voltage
Auto Equalize
Charge
Equalize Voltage
Equalize Duration
Temperature
Compensation
Overvoltage
Alarm
Undervoltage
Alarm On Value
Undervoltage
Alarm Off Value
Undervoltage
Alarm Delay Time
1)
Multiply all voltage values by a factor of 2 for 24V systems
When different charge program parameters are desired, the Custom (USE) battery type can be
selected. For further parameter explanations or info on how to create a Custom charge program,
please download the Omnicharge Solar user manual from our website.
Invalid battery type settings can cause serious damage to your batteries and/or connected
battery loads. Always consult your battery's documentation for the correct charge voltage
settings.
3.2
Battery type selection and solar charger reset
The battery type can be changed in two ways. This can be done using the recessed setup button at
the bottom of the solar charger, or by using the TBS Dashboard Mobile app. In this installation
manual we will only explain the setup button method. Connection to the Dashboard Mobile app will
be explained further in the Omnicharge Solar user manual that can be downloaded from our
website.
To enter the battery type setup mode, the setup button must be pressed for at least 8 seconds. After
this 8 seconds the battery type LED starts flashing and the setup button can be released. Each time
the setup button is pressed again, the color of the battery type LED will change according to the
table shown in chapter 3.1. Once the desired battery type color has been reached, the setup button
must be pressed for 8 seconds again to save the new setting. This new setting is also saved
automatically when the setup button has not been touched for more than 15 seconds.
The setup button can also be used to reset the solar charger completely to factory default settings.
To do this, the setup button needs to be pressed for at least 20 seconds. A successful factory reset is
confirmed once all three LEDs shortly start to flash in red. Then the setup button can be released.
13.6V
13.2V
-
-
-
-3mV/°C/cell
-3mV/°C/cell
16.0V
11.6V
12.4V
6 seconds
6 seconds
!
13.4V
13.4V
13.2V
13.2V
-
30 days
-
14.8V
-
120 minutes
-3mV/°C/cell
16.0V
16.0V
11.6V
11.6V
12.4V
12.4V
6 seconds
CAUTION
12
-
13.2V
-
-
-
-
16.0V
12.0V
12.4V
6 seconds