• Float Voltage → Enter the desired float voltage
• Restart Voltage → Enter the desired restart voltage
• Auto Equalize Charge → Off
• Equalize Voltage → Enter the same value as Charge Voltage
• Equalize Duration → 10min (do not set to 0min.!)
• Temperature Compensation → Not Compensated
• Undervoltage Alarm On Value → Enter the desired voltage
• Undervoltage Alarm Off Value → Enter the desired voltage
• Undervoltage Alarm Delay Time → Enter the desired time
The parameters indicated in
functionality.
3.3
Overview of factory default charge program parameters
Please see the table below for an overview of the main factory default parameter values of each
battery type:
Parameter
Charge Voltage
Absorption Time
Float Voltage
Restart Voltage
Auto Equalize
Charge
Equalize Voltage
Equalize Duration
Temperature
Compensation
Overvoltage
Alarm
Undervoltage
Alarm On Value
Undervoltage
Alarm Off Value
Undervoltage
Alarm Delay Time
1)
Multiply all voltage values by a factor of 2 for 24V systems
red
are very important. Please use exactly these values for correct
AGM (SLD)
14.6V
120 minutes
120 minutes
13.6V
13.2V
-
-
-
-3mV/°C/cell
-3mV/°C/cell
16.0V
11.6V
12.4V
6 seconds
6 seconds
1)
Battery type
GEL
Flooded (FLD)
14.2V
14.4V
120 minutes
13.4V
13.4V
13.2V
13.2V
-
30 days
-
14.8V
-
120 minutes
-3mV/°C/cell
16.0V
16.0V
11.6V
11.6V
12.4V
12.4V
6 seconds
17
Lithium /
LiFePo4 (LI)
14.4V
-
-
13.2V
-
-
-
-
16.0V
12.0V
12.4V
6 seconds