H YGI E N E RI N SE
The hygiene rinse opens the faucet for 10 seconds
every 24 hours following the last use.
To enable or disable the hygiene rinse:
⁄ Disconnect the electrical plug connection between
fitting and battery housing. During this time, briefly
reach with your hand into the detection area of the
sensor window so that the capacitor discharges.
Restore the power connection after 10 seconds.
⁄ The LED blinks to indicate the software version (e.g.
blinking once = software version 1).
⁄ The LED will come on constantly while the faucet
calibrates. WAIT FOR THE LED TO GO OUT.
⁄ Cover the sensor window completely with your hand
or a piece of white paper for 5 - 10 seconds. Water
will flow from the faucet for 5 seconds.
⁄ Uncover the sensor window.
⁄ The currently enabled mode is indicated by the flash-
ing of the LED: 1 x = hygiene rinse is enabled, 2 x =
disabled.
⁄ A subsequent change of operating mode is possible
again after calibration.
⁄ The fitting returns to normal operation 60 seconds
after the last change of operating mode.
P E RMA N E N T RIN S E
After setting the parameters for the hygiene rinse or
making a net reset, wait for approx. 100 seconds be-
fore you can enable the "Permanent rinse" function.
⁄ Cover the sensor window completely with your hand
or a white piece of paper.
⁄ The faucet opens briefly and then closes immedi-
ately. When the faucet opens again after approx.
5 seconds, remove the hand or the paper from the
sensor.
⁄ Permanent rinse is enabled for 3 minutes and can be
interrupted at any time by a movement in the sensor
range.
THE RMAL DISINFECTION
Ther mal d i si nfec t i on m us t o nl y be c a r r ie d
ou t by q u al i f ied p ersonne l .
⁄ Risk of scalding with thermal disinfection!
⁄ The cold water stop must be closed during thermal
disinfection.
⁄ Afterwards, "Permanent rinse" can be enabled.
N ET RE SET
⁄ A "net reset" returns the faucet to the original factory
settings.
⁄ Interrupt the voltage supply to the faucet.
⁄ Briefly reach into the sensor range of the faucet to
discharge the capacitor.
⁄ Wait for approx. 10 seconds, then plug the connec-
tors in again.
The fa ucet wil l re -a d j us t d ur i ng t h e nex t
3 0 seco nd s. Do n ot rea ch i nto t h e se n-
sor rang e d ur i ng t h is p er io d of t i m e .
3