WARNING
Do not exceed the rating of the power outlet or connection device.
Do not operate or stop the unit by switching on or off the power.
Do not damage or use an unspecified power cord.
Do not modify power cord length or share the outlet with other appliances.
Do not insert or pull out plug with wet hands.
Do not install the appliance in a location that may be exposed to
combustible gas.
Do not place the unit near a heat source.
Disconnect the power if strange sounds, smell, or smoke comes from it.
You should never try to take apart or repair the unit by yourself.
Before cleaning, turn off the power and unplug the unit.
Do not use the machine near flammable gas or combustibles, such as
gasoline, benzene, thinner, etc.
Do not drink or use the water drained from the unit.
Do not take the water bucket out during operation.
Do not use the unit in small spaces.
Do not put in places where water may splash onto the unit.
CAUTION
This appliance is not intended for use by persons (including childern) with
reduced physical, sensory or mental capabilities or lack of experience and
knowledge, unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the
appliance.
If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
Prior to cleaning or other maintenance, the appliance must be
disconnected from the supply mains.
CAUTION
In a thunderstorm, the power must be cut off to avoid damage
to the machine due to lightning.
Do not run cord under carpeting. Do not cover cord with throw
rugs, runners, or similar coverings. Do not route cord under
furniture or appliances. Arrange cord away from traffic area
and where it will not be tripped over.
Do not operate unit with a damaged cord or plug. Discard
unit or return to an authorized service facility for examination
and/or repair.
To reduce the risk of fire or electric shock, do not use this fan
with any solid-state speed control device.
The appliance shall be installed in accordance with national
wiring regulations.
Contact the authorised service technician for repair or
maintenance of this unit.
Turn off the product when not in use.
Place the unit on a level, sturdy section of the floor.
Do not cover the intake or exhaust openings with cloths or towels.
Care should be taken when using the unit in a room with the
following persons: infants, children, elderly people,and people not
senstive to humidity.
Do not use in areas where chemicals are handled.
Never insert your finger or other foreign objects into grills or
openings. Take special care to warn children of these dangers.
Do not place heavy object on the power cord and take care so
that the cord is not compressed.
Do not climb up on or sit on the unit.
Always insert the filters securely. Clean filter once every two weeks.
If water enters the unit, turn the unit off and disconnect the power ,
contact a qualified service technician.
Do not place flower vases or other water container on top of
the unit.
Do not use extension cords.
Do not install the appliance in a location that may be exposed
to combustible gas. If combustible gas accumulates around the
unit, it may cause fire.
If the appliance is knocked over during use, turn off the unit and
unplug it from the main power supply immediately. Visually
inspect the unit to ensure there is no damage. If you suspect the
unit has been damaged, contact a technician or customer
service for assistance.
The manufactures nameplate is located on the rear panel of
the unit and contains electrical and other technical data s
pecific to this unit.
Be sure the unit is properly grounded. To minimize shock and
fire hazards, proper grounding is important. The power cord
is equipped with a three-prong grounding plug for protection
against shock hazards.
Your unit must be used in a properly grounded wall receptacle. If the
wall receptacle you intend to use is not adequately grounded or
protected by a time delay fuse or circuit breaker(please refer to the
nameplate for the electrical data), have a qualified electrician install
the proper receptacle.
Do not operate your air conditioner in a wet room such as a
bathroom or laundry room.
The unit s circuit board(PCB) is designed with a fuse to provide
overcurrent protection.specifications of the fuse are printed on the
circuit board, such as:T 3.15A/250V (or 350V), etc.
7
7