6. STOPPING THE ENGINE
Turn off all electrical appliances connected to the generator and wait
50 seconds.
2. Disconnect all electrical appliances from the generator.
3. Turn the generator switch to the OFF position.
4. Turn the fuel flow switch to OFF.
WARNING: Do not touch any of the hot components until the
unit is turned off and has cooled completely to avoid burns.
CAUTION: Do not keep the fuel inside the unit for a long time as it will be difficult to start the engine.
If you are not going to use the generator for a while, remove the fuel.
7. MAINTENANCE
You must maintain the unit according to the following maintenance schedule:
Element
Spark plug
Fuel
Exhaust pipe
Motor oil
Air filter
Muffler cover
Spark catcher
Combustion chamber
Valve clearance
Adjustments and
tightening
Fuel pipe
30
Each use
Check status. Clean or replace if
necessary
Check fuel level for leaks
Check that the tube is not da-
maged or blocked, and replace
if necessary
Check the level
Replace
Check status and clean
Check status and clean or repla-
ce if necessary
Check status and clean or repla-
ce if necessary
Clean the chamber of deposited
carbon
Check and adjust with the
engine already cold
Check all connections and
screws. Adjust if necessary.
Check status
Every 20 h. or
Every 50 h or
1st month
every 3 months
(*1)
(*2)
Once a year (replace if necessary)
Every 100 h or
every 6 months