Descargar Imprimir esta página

schmersal AZM300B-I2-ST-SD2P-DU Instrucciones De Operacion Y Montaje página 6

Publicidad

Safety functions
Integral system diagnostics, status
Number of actuating directions
Number of fail-safe digital outputs
Safety classification
Standards
Safety classification - Interlocking function
Performance Level, up to
Category
PFH value
PFD value
Safety Integrity Level (SIL), suitable for applications in
Mission time
Mechanical data
Mechanical life, minimum
Note (Mechanical life)
Angular misalignment between solenoid interlock and actuator,
maximum
Holding force F
in accordance with EN ISO 14119
Zh
Holding force F
, maximum
max
Latching force, adjustable, position 1
Latching force, adjustable, position 2
Type of the fixing screws
Tightening torque of the fixing screws, minimum
Tightening torque of the fixing screws, maximum
Mechanical data - Switching distances according EN IEC 60947-5-3
Switch distance, typical
Assured switching distance "ON" S
Assured switching distance "OFF" S
Mechanical data - Connection technique
ao
ar
3
2
EN ISO 13849-1
EN IEC 61508
e
4
5,20 x 10⁻¹⁰ /h
4,50 x 10⁻⁵
3
20 Year(s)
1.000.000 Operations
Si se utiliza como tope de resguardo: ≥ 50.000 maniobras (con
pesos de resguardos ≤ 5 kg) y velocidad de accionamiento ≤ 0.5
m/s)
2 °
1.150 N
1.500 N
25 N
50 N
2x M6
6 Nm
7 Nm
2 mm
1 mm
20 mm
6-29

Publicidad

loading