To connect the device to the power supply, use the cable coming out of the
appliance. At its extremity it will be sufficient to connect a suitable plug
equipped with a ground terminal or use the socket included, if present.
Avoid the use of extensions. The power socket to which the battery charger
will be connected must be proportionate to the power of the same charger and
must have incorporated fuses or other standard protection.
Check the plate data regarding:
V– (power supply voltage), KVA (power) and A– (current).
Make sure the ground connection is correct. Any replacement of the power
cable must be performed by competent and authorized personnel.
WARNING! Before connecting the battery make sure that the charger has
been properly programmed by qualified personnel.
Contact your POLAR dealer.
Be careful not to invert the cables when connecting the battery terminals: for
this connection it is advisable to use the appropriate one-way connectors.
Make sure that the contacts between the cables and the connectors, both
towards the power supply and the battery, are in good condition.
The Q-SERIES inverter battery chargers are protected by:
-Polarity inversion by means of electronic protection and replaceable fuse.
If a connection to the battery is mistakenly made with reverse polarity,
the polarity inversion warning will appear on the display together with
a repeated audible "beep" sound.
Polar Q2 and Q4 battery chargers are equipped with reverse polarity
protection only by externally replaceable fuses.
- Accidental breakages, via fuse on the power supply network
- Overloads and short circuits on the output, via electronic protection and fuse
on the direct current circuit
- Overheating of the battery charger, in the event of environmental factors
or occlusions of the cooling system causing overheating, the charger will
gradually decrease the output power without interrupting the charge.
Maintenance must be carried out by specialized and authorized personnel.
Control and verification inspections must be carried out in relation to the
environment and the operating conditions.
Before starting inspections and maintenance, make sure that the battery
and the power supply are disconnected.
CONNECTION TO THE POWER NETWORK
CONNECTION TO THE BATTERY
PROTECTION DEVICES
MAINTENANCE