SPECIFICATIONS
Typical test conditions, unless otherwise specified: Ambient Temp =73+/-3°F (22 +/-3°C), RH=50%–
70%, Altitude=0~100 meter
MEASUREMENT
Operating Temperature
Storage Temperature
Designed For
Operating & Storage RH
Accuracy at 0~3000 ppm
Accuracy over 3000 ppm
Repeatability
Measurement Range
Display Resolution
Temp Dependence
Pressure Dependence
Response Time
Warm-up Time
Back-Lit Display
Power Input/Output
Main Supply Voltage
Applicable Pollution
Dimensions
Weight
DISCLAIMERS
This device is not intended for workplace hazard CO
for human or animal health institutions, life sustenance, or any medical-related situation.
Hydrofarm and the manufacturer assume no responsibility for any damage or loss suffered by the user
or any third party arising through the use of this product or its malfunction.
Hydrofarm reserves the right to change the specifications without notice.
Manufactured for: HYDROFARM LLC
Address: 1304 Southpoint Blvd Suite 200
Petaluma, CA 94954
PAY ATTENTION TO ELECTRICITY SAFETY.
OPERATING INSTRUCTIONS
32°F to 104°F (0°C to 40°C)
-4°F to 140°F (-20°C to 60°C)
Indoor Use
0–95%, non-condensing
CO
Measurement
2
±50 ppm or ±5% of reading, whichever is greater
±7%
20 ppm at 400 ppm (standard dev. of 10 readings in 1 minute)
0–5000 ppm
1 ppm (0–1000); 5 ppm (1000–2000); 10 ppm (>2000)
±0.2% of reading per °C or ±2ppm per °C, whichever is greater,
referenced to 25°C
0.13% of reading per mmHg (corrected by user's altitude input)
<2 min for 63% of step change or <4.6 min for 90% step change
<30 seconds
The green back-lit display automatically turns off during the dark
period. Pressing any button during the dark period will illuminate the
screen for 30 seconds.
AC 120VAC, 60Hz, Current: 10A Max
Fluctuations up to ±10% of the nominal voltage
Degree of the intended environment (POLLUTION DEGREE 2)
Socket Unit: 115 x 45 x 38 mm (4.5" x 1.8" x 1.5")
Control Unit: 195 x 145 x 44 mm (7.7" x 5.7" x 1.7")
760 g (26.8 oz)
2
6
SPECIFICATION
monitoring, nor intended as a definitive monitor

Publicidad