INSTALLATION INSTRUCTIONS
4. Connect the ground conductor (green wire)
under the terminal B. Then connect the neutral
wire (white wire) to center of the terminal. Neutral
ground conductor of the dryer should remain on
the center terminal. Ensure the neutral ground
conductor of the dryer and neutral wire of the
supply cord are connected to the center terminal
together. Tighten all screws.
5. Connect remaining wires under the outer
terminals of the block and tighten all screws. After
every connection is completed, tighten the strain
relief clamp in order to secure the supply cord.
Finally, cover up the box cover.
3-WIRE POWER SUPPLY CORD
WARNING
• Before the connection, disconnect the power.
• Use UL listed 240V / 30A power supply cord.
The dryer is equipped with strain relief. Use this
strain relief for the connection.
1. Remove the screw and terminal box cover.
2. Remove the clamp of the strain relief which is
attached on the machine. Pass the clamp through
the supply cord and put the supply cord through
the main body of the strain relief. Ensure the wire
insulation of the cord is inside the strain relief.
3. Remove the terminal block screws which are
indicated by A and the grounding screw which is
indicated by B. Neutral ground conductor (central
terminal) is provided in the dryer as a closed loop.
4. Remove the neutral ground conductor from the
central terminal and connect the neutral wire of the
supply cord under the central terminal of the block.
Tighten the screw.
5. Connect the neutral ground conductor under the
screw B. Then connect the remaining supply cord
wires under the outer terminals of the block. Tighten
all screws. After every connection is completed,
tighten the strain relief clamp in order to secure the
supply cord. Finally, cover up the box cover.
8