SFA ZPS 2.3 Instrucciones De Manejo Y De Montaje página 12

Ocultar thumbs Ver también para ZPS 2.3:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 78
1st line on display
20 mA => level
Signal contact 1-4
Language
DD.MM.YYYY
hh:mm
Keylock
WLAN reset
Fault protocol
3.1.5 Information retrieval
The following table shows the signification of the operational data of the control system :
1st line on display
up time
total pump hours
pump starts
next maintenance
2nd line on display
(set value)
1 - 1250 cm
Possible signals :
- Fault high water
- Collective fault
- Pump 1 on
- Pump 2 on
- Fault pump 1
- Fault pump 2
- system OK
Deutsch
English, etc...
see adjustments
on / off
- - -
2nd line on display
(informational value)
hours: X
(in hours)
P1/P2 XXXX/XXXX
(in hours)
P1/P2 XXXX/XXXX
(in number)
within days:XXXX
(in days)
Signification
Final value of the sensor at 20 mA
Kind of signal on contacts 1-4
The collective fault signal can be timed
Setting of the menu language
Date and time
The keylock can be disabled. The key lock is
enabled with the service mode switched-off
only.
Disabled
After having pressed the key
protocol can be paged through by pressing
the keys
.It is not possible to
change the data. The last 32 malfunctions
are saved in chronological order.
Signification
Shows the cumulative operating times of the
control system in hours. The value can be
reset to 0 by pressing the keys
Shows the cumulative runtimes of the
pumps in hours. The value can be reset to 0
(separately for both pumps)by pressing the
keys
.
Shows the number of pump starts. The
value can be reset to 0 (separately for both
pumps) by pressing the keys
Shows the number of days until the next
maintenance. The information is saved at
intervals of 4 hours. The initial value can be
preset between 365 and 0 days.
, the
.
.
11