Principle Diagram - Lamborghini Caloreclima FUTURIA 24 PLUS MB W TOP Manual Para La Instalación Y El Mantenimiento

Ocultar thumbs Ver también para FUTURIA 24 PLUS MB W TOP:
Tabla de contenido

Publicidad

PRINCIPLE DIAGRAM

LEGEND
CiR
System circulating pump
Safety gas pressure switch
PSG
Air pressure switch
PA
PH
O
Water pressure switch
2
E.A.
Ignition electrode
Detection electrode
E.R.
Transformer
TRA
IG
Main switch
VG1
Gas valve 1
VG2
Gas valve 2
3-way valve
VD
E/I
Summer/winter switch
TA
Room thermostat
TB
Water-heater thermostat
External sensor
SE
SR
Return sensor
Delivery sensor
SM
Fan
VN
X2
Amp. 13-pole connector
X3
Amp. 6-pole connector
Amp. 2-pole connector
X4
X7-X8 PC connector
3AT
Fuse 3A (electric fan)
2AF
Fuse 2A (24 V circuits)
2AF(F1) Power supply fuse 230 V (2 A)
Line 230 V 50 Hz
L
N
Neutral
C
Connector Wieland
FA
Anti-interference filter
39