Phase N
3
Central heating system
Delivery temperature (T1)
4
T1
(minimum heating temperature)
5
foot
T4 minimum (settable outdoor sensor tem-
6
perature)
7
Pause temp. for heating re-ignition
Parallel shift (with outdoor sensor and on-
8
boiler timer)
9
Central heating hysteresis
Heating re-ignition waiting time
A
b
Post-circulation time. Pump in heating mode
C
PWM pump
Boiler type
1, figure as in heating
d
2, figure as in Hot water
E
Fan speed control
Min/max r.p.m. in heating mode
F
Parameter
When setting has been
completed press
Range
00 = Central heating off
01 = Central heating on
02 = Central heating on and pump in
cont. mode
From 20°C to 90°C
From 15°C to 25°C (recommended 15°C)
From -20°C to +10°C
From 15°C to 30°C
From 0°C to 30°C (on T
From 5°C to 15°C
From 0°C to 30 (x 10 .2 seconds)
From 3 to 99 minutes
Do not use
0x = room thermostat
1x = NTC4 sensor (outdoor sensor)
x0 = 3-way valve
x1 = Hot water pump – Do not use
x2 = inverted 3-way valve – Do not use
00 = modulation working. From 01 to
100% manual fan speed control. Chimney-
sweep function.
From 10 to 60 (x 100)
49
)
set