START/RESTART WAIT
SWITCH ON RESTART
HOT SMOKE
OFF
WAIT FOR PELLETS
OUT OF
INFEED SCREW
OVERFLOW
GENERIC ALARM
ANOMALY (general)
AUTOMATIC CLEANING
SYSTEM ACTIVE
Warning Pop -Up
ANOMALY
SERVICE REQUEST
Alarms (table with reference codes)
TITLE
AL 01
BLACK OUT
AL 02
K PROBE
FAILURE
AL 03
OVERTEMP. K
Use and maintenance manual Classic 7-9
Switch-on is requested but with the stove in cooling phase; once this condition is
met, it restarts automatically.
The HOT restart phase is activated.
Functioning is similar to the SWITCH ON phase
The maximum fume temperature threshold has been reached. To facilitate cooling,
the stove brings the capacity to a minimum with ventilation at power level 5, leading
to a decrease in fume temperature.
The stove is off
When the switch-on request from ECO-STOP mode coincides with an automatic
switch-off condition (from the TIMER), the stove turns on ensuring total cleaning of
the brazier before switching to FINAL CLEANING.
CONDITION: when the pellet setting (set pellets +5) is near the continuous load
condition.
SOLUTION: Set the value back to 0.
The stove is in alarm state; refer to the troubleshooting chapter.
The stove has detected an anomaly; refer to the troubleshooting chapter.
For models with automatic cleaning system it indicates the operating state of the
same.
DESCRIPTION
The threshold value of set work hours has been reached. The symbol displayed
remains active throughout the work phase. Non-routine maintenance is required
on the stove.
REASON
No voltage during work phase
The K probe is malfunctioning
The K probe is disconnected from the
electronicboard
Combustion in the brazier is not optimal due to
clogging or obstructions of internal stove ducts
inside the stove
SOLUTION
Press the switch off key and switch on the stove
again
If the problem persists, contact the Support Service
Contact the Support Service
Contact the Support Service
Switch off the stove, clean the brazier and the tube
bundle and adjust the combustion setting the Pellet/
Air values
Contact the Support Service
If the problem persists, contact the Support Service
Rev.1 06.02.18
Page 71
EN