Logic
Definition
Open in other
OPEN IN OTHER
direction
DIRECT.
Configuration
of safety input
SAFE 1
SAFE 1.
72
Configuration
of safety input
SAFE 2
SAFE 2.
74
Configuration of
command input
IC 1
IC 1.
61
Configuration of
command input
IC 2
IC 2.
62
Configuration of
AUX 0 output.
AUX 0
20-21
Fixed code
FIXED CODE
www.BFTGateOpeners.com | (800) 878-7829 | Sales@BFTGateOpeners.com
INSTALLATION MANUAL
Cross out
De-
setting
fault
used
0
Standard operating mode (See Fig.Q Ref. 1).
0
1
Opens in other direction to standard operating mode (See Fig. Q Ref.2)
1
Input configured as Phot test (tested photocell).
1
5
Input configured as Phot cl test (tested photocell active during closing only).
0
Input configured as Phot (photocell).
1
Input configured as Phot test (tested photocell).
2
Input configured as Phot op (photocell active during opening only).
3
Input configured as Phot op test (tested photocell active during opening only).
4
Input configured as Phot cl (photocell active during closing only).
5
Input configured as Phot cl test (tested photocell active during closing only).
6
Input configured as Bar, safety edge.
7
Input configured as Bar, tested safety edge.
8
Input configured as Bar 8k2.
Input configured as Bar OP, safety edge with inversion active only while opening. If while closing, the mo-
6
9
vement stops.
Input configured as Bar OP TEST, safety edge tested with inversion active only while opening. If while closing,
10
the movement stops.
Input configured as Bar OP 8k2, safety edge with inversion active only while opening. If while closing, the
11
movement stops.
Input configured as Bar CL, safety edge with inversion active only while closing. If while opening, the mo-
12
vement stops.
Input configured as Bar CL TEST, safety edge tested with inversion active only while closing. If while opening,
13
the movement stops.
Input configured as Bar CL 8k2, safety edge with inversion active only while closing. If while opening, the
14
movement stops.
0
Input configured as Start E.
1
Input configured as Start I.
0
2
Input configured as Open.
3
Input configured as Close.
4
Input configured as Ped.
4
5
Input configured as Timer.
6
Input configured as Timer Pedestrian.
0
Output configured as 2nd Radio Channel.
1
Output configured as SCA (gate open light).
2
Output configured as Courtesy Light command.
3
Output configured as Zone Light command.
4
Output configured as Stair Light
6
5
Output configured as Alarm
6
Output configured as Flashing light
7
Output configured as Latch
8
Output configured as Magnetic lock
9
Output configured as Maintenance
10
Output configured as Flashing Light and Maintenance.
Receiver is configured for operation in rolling-code mode.
0
Fixed-Code Clones are not accepted.
0
Receiver is configured for operation in fixed-code mode.
1
Fixed-Code Clones are accepted.
Optional extras
ARES ULTRA BT A 1500 - 1500 V
25