Keypad deadbolt
»
Locking and unlocking
LITHIUM BATTERIES?
Lithium
batteries may
From the outside:
have a longer
life, but when
they begin
to fail, they
fail quickly.
We don't
recommend
them because
they don't give
you a lot of
time to change
your batteries
before the lock
is completely
dead.
Changing the battery
»
Key Override
Key Override can be used to gain access when the battery is completely dead, when no valid User
Code is known.
6 • Enter brand in text variables • Enter document title in text variables
To Lock
1
Press the
2
Schlage
button.*
*
If the Turn Lock feature is disabled, a valid User Code must be entered to lock the door.
& Leave
on page 11.
Replace the batteries in your lock at the same time each year that you test and replace the
batteries in your smoke alarms. This will ensure continued reliable operation. Use a high-quality
alkaline 9 volt battery for replacement.
1
Remove the
inside cover.
1
Insert the
key into the
cylinder.
Reverse steps to relock. Hold the thumbturn still while removing the key. See Changing the Battery on page 7 or
Restore Factory Settings on page 13 for more information.
To Unlock
»
If lighting is low, press the Schlage button to
illuminate the keypad before beginning.
Rotate the
1
thumbturn away
from the hinges.
2
Replace the
battery.
2
Rotate the
3
key 90°
toward the
hinges.
Enter a User
2
Rotate the
Code into the
thumbturn toward
keypad.
the hinges.
Enable or Disable Lock
See
3
Re-tuck wires so they will not
be crimped. Replace the cover.
Push the key and
4
cylinder into the
thumbturn.
Rotate the
thumbturn
90° toward the
hinges.

Publicidad