Descargar Imprimir esta página

Thulos TH-EXT12 Manual De Instrucciones página 14

Estufa de gas

Publicidad

POSITION AND LOCATION
This stove is for outdoor use and is covered exclusively.
Make sure you have sufficient ventilation Keep a safe distance between the stove and
combustible materials Recommended: 100 cm (top) and 100 cm (side) minimum.
The stove must be located on a firm and level floor.
To protect the stove from strong winds, secure the base to the floor with screws.
GAS CHARACTERISTICS
Use butane or propane only.
We recommend the use of Propane, since it has a lower freezing point, suitable for outdoor
appliances. The regulator and the rubber tube with clamps must follow the regulations in
force in each country. The installation must be under local regulations. In the absence of this,
it must be carried out according to the standard of storage and use of Liquefied Petroleum
Gases. A cracked, rusted or damaged cylinder can be dangerous and must be checked by
the manufacturer or supplier. Never use a cylinder with a bad valve.
The gas connections of the stove have been previously checked by the manufacturer before
shipment. A safety check should be performed during installation at the place of use to
avoid parts loosening due to shipment.
LEAK CHECK
Make a soapy solution one part water and one part soap.
The soapy solution can be applied with a spray bottle, brush or cloth.
Soap bubbles will appear in the event of a leak.
The stove must be checked with a full cylinder.
Make sure the knob is in the off position.
Open the gas flow from the regulator. In the event of a leak, close the gas supply to the
regulator. Tighten the connections with the corresponding clamps. Open the gas passage
again to check again. Repeat until the leak disappears.
Do not smoke during the leak test.

Publicidad

loading