Electrical Connection
1. Your oven requires 40 Amp fuse for mono phase or 3x16 Amp fuse
for 3 phase supply according to electrical power for cooker section has
4 ceramic heater and oven section has electric models. Installation by a
qualified electrician is mandatory.
2. Your oven is adjusted in compliance with 220-240V / 380-415V
AC,50/60Hz. electric supply. If the mains are different from this specified
value, contact your authorized service.
3. Electrical connection of the oven should only be made to connections /
sockets with an earth system installed in compliance with local regulations.
If there are no connections/sockets with an earth system in place where
the oven will be installed, immediately contact a qualified electrician to
install. The manufacturer is not responsible for damages that will arise
because of the appliance not be connected to an earth system.
4. If your supply cable gets damaged, it should be replaced by an
authorized service agent or qualified electrician in order to avoid danger
or electric shock.
5. Electrical cable should not touch the hot parts of the appliance.
6. Operate your oven in dry atmosphere.
7. When placing your oven to its location, ensure that it is at the counter
level. Bring it to the counter level by adjusting the feet if necessary.
Electrical Connection Scheme
220-240V~50/60Hz
380-415V 3N~50/60Hz
Neutral
Neutre
Live
Earth
Phase
Terre
Erdung
H05 VV-F 3G 4 mm²
380-415V 2N~50/60Hz
Neutral
L3
L2
Neutre
L2
Earth
L1
L1
Terre
Erdung
H05 VV-F 5G 1.5 mm²
H05 VV-F 4G 1.5 mm²
14
220-240V~50/60Hz
Neutral
Neutral
L
N
Neutre
Neutre
Earth
Earth
Terre
Terre
Erdung
Erdung
H05 VV-F 3G 4 mm²