You will get a good level of satisfaction in the work
performed with the Remover following the instruc-
tions of the present manual.
The WARRANTY is valid for two years, counted
as of the date of purchase, which will be indica-
ted by the seller in the place provided for this
purpose, together with his stamp
This WARRANTY covers any manufacturing
defect, which will be repaired without charge.
However, any malfunction resulting from the inco-
rrect use of the unit, such as inadequate connec-
tions, breakage due to dropping, or similar, the
normal wear of components and in general any
deficiency not attributable to the manufacturer of
the device, are expressly excluded.
Likewise, the WARRANTY shall be rendered null
and void when it is evident that the unit has been
handled by persons other than our Technical
Assistance Service.
This WARRANTY does not support any undertaking
made by anyone outside our Technical Service.
In the case of any breakdown during the guaran-
tee period, please attach the completed warranty
ANOMALIES
Motor weak
Motor stopped
The motor stops
The motor overheats
13. OBSERVATIONS
Should you have any doubt, please contact the
Technical Service of SAGOLA.
14. WARRANTY CONDITIONS
certificate to the unit and deliver this to the
nearest Technical Assistance Service or get in
touch with the factory.
Any demand of greater importance against the
supplier, in particular compensation for dama-
ges, is excluded.
This is also applicable to any damages that might
arise during counselling, while acquiring practice
and during demonstration.
Consequently, the services rendered under
guarantee do not involve an extension of the
warranty period.
Any device for which there is no duly completed
guarantee certificate in the files of SAGOLA S.A.
will be rejected.
The manufacturer reserves the right to make tech-
nical modifications.
15. TROUBLESHOOTING
CAUSES
Filter clogged
Inversion piston worn
Insufficient compressed air
Product very dense
Motor dirty
Insufficient compressed air
Regulation valve closed
Output silencer filter clogged
Air pressure reduced for the
viscosity used
Pinion or crown deteriorated
Output silencer filter clogged
Low oil level
High product viscosity
Oil in poor condition
- 24 -
REMEDY
Change or clean the silencer filter
Replace
Regulate the air pressure
Reduce the viscosity of the product
Clean the pneumatic motor
Connect the compressed air
Open the regulation valve
Change or clean the silencer filter
Increase the air pressure
Change both parts
Change or clean the silencer filter
Top up the oil
Reduce its thickness
Change the oil