Descargar Imprimir esta página

Samoa 186 310 Guía De Servicio Técnico Y Recambio página 2

Pistola multifluido

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
INTRODUCTION
CAUTION: EQUIPMENT MISUSE
• This unit is intended for professional use. Read all the
instructions in this manual prior to use.
CAUTION: CHEMICAL COMPATIBILITIES
• Use the unit with fluids and solutions which are
compatible with the unit wetted parts. Please refer to
the technical specifications relevant section.
WARNING: PRESSURE LIMITS
• Release all pressure within the system prior to
performing any maintenance or disassembly operation.
DESCRIPTION
• The control valve is designed to dispense a variety of
low viscosity fluids and critical fluids that demand a
high grade of chemical compatibility, among which are
urea, winshield washer fluid, glycol, antifreeze, distilled
water, brake fluid, etc.
• The control valve has a compensated valve that allows
progressive actuation for better flow control.
MOUNTING AND INSTALLATION
• To ensure the sealing, mount the extension outlet using
the provided FKM o-ring, taking care that the position
of the o-ring housing is correct (figure 1). Lubricate the
o-ring before mounting.
• To connect the gun to the network, keep fixed the gun
body and the hose end while rotating the swivel free
2
896 854 R. 03/23
SAMOA Industrial, S.A. · Pol. Ind. Porceyo, I-14 · Camino del Fontán, 831 · 33392 - Gijón - Spain · Tel.: +34 985 381 488 · www.samoaindustrial.com
• Only use the unit for the purposes for which it is intended.
• Do not tamper the unit.
• Observe the manufacturer's safety warnings for the
fluids used.
• Do not exceed the maximum unit working pressure.
See technical specifications section.
• The valve can be locked in open position by means of
the trigger cam.
• The gun includes protection to prevent accidental
opening. Refer to the operation section for details
of operation.
• All guns include 1/2" BSP threaded swivel, an extension
outlet and a filter inside.
end to achieve the desired torque. Tightness is achieved
through the application of sealant or PTFE tape (Fig. 2).
• A meter unit can be attached to the gun by means of
the gun flange. Employ a 24 x 2 mm size o-ring (1) and
two M5 x 14 screws (2) for mounting.
Fig. 1

Publicidad

loading