Descargar Imprimir esta página

Nordcap MORETTI iDeck PD 105.65 Manual De Instrucciones página 15

Ocultar thumbs Ver también para MORETTI iDeck PD 105.65:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

- insert the screws and nuts and lock the whole assembly,
- bring up the short top elements, insert all the screws and lock,
Detail D
- check that all the screws are tightly locked,
- insert the plugs at the ends of the tubular elements,
- insert plugs into all the holes on the outside of the tubular elements.
Fitting the Optional Wheel Kit:
- turn the frame on its side and fix each wheel connector using the
screws provided,
- fix the wheels to the connector using the screws; the rotating wheels
with brakes go at the front and the fixed wheels go at the back,
- check that all the screws are tightly locked.
2.5
CONNECTIONS
2.5.1
VAPOUR EXHAUST CONNECTION
WARNING!
Connection of the vapour exhaust must only
be carried out by specialised personnel.
The vapour exhaust pipe is located at the rear of the oven (item C -
fig.8). Insert the perforated ring (item B - fig.8) into the vapour exhaust
outlet and connect.
NOTE:
It is recommended that you connect the vapour
exhaust to a flue or to the outside using a pipe with a minimum
diameter
of
100
mm
(72.72/65.105/105.105/105.65).
This pipe (item A - fig.8) must be inserted into the oven exhaust outlet
by means of the ring. Any extensions must also be connected so that
the upper pipes fit into the lower ones, as illustrated for the connection
described above.
If the external vapour exhaust pipe is very long, it is advisable to fit a
small plastic tube at the base of the pipe itself to drain off any
condensation (item D - fig.9). This operation must be carried out
before coupling the pipe to the outlet.
2.5.2
ELECTRICAL CONNECTION
WARNING!
Electrical connection must only be carried out
by specialised personnel, in compliance with current local state
Electric Quality Assurance Corporation requirements.
Before starting the connection procedure, check that the earthing
system is provided in accordance with European EN standards.
Before starting the connection procedure, check that the main
power switch for the supply to which the machine is to be
connected has been turned to the "off" position.
The rating plate contains all the information necessary for proper
connection.
2.5.2.1 ELECTRICAL CONNECTION OF THE BAKING
CHAMBER
WARNING!
Each of the cooking elements must be fitted
with a main four-pole switch with fuses or an automatic switch
suitable for the values shown on the plate and to allow the single
appliances to be disconnected from the mains, that provide full
disconnection under overvoltage category III conditions.
NOTE:
The device selected should be in the immediate vicinity
of the oven and within easy access.
NOTE:
The sheath of the power supply cable must prevent
that the conductors in basic insulation come in contact with the
surrounding metal parts. The ground conductor must be 50mm
longer than the power supply conductors. The supplied presscable
can clamp a cable with a diameter between 12 and 19mm.
The baking chamber is delivered with the required voltage indicated on
the rating plate (fig. 2).
WARNING!
(60.60) For any voltage changes, always
contact
qualified
service
Manufacturer. Affix the decal provided (FIG. 25) to the nameplate
(FIG. 2), according to the required voltage.
To carry out electrical connection, remove the protective cover located
on the rear side of the baking chamber (fig.10).
The connection cable must be supplied by the installer.
When connecting to the power mains, it is necessary to fit a plug that
complies with the standards and regulations in force.
Insert a cable with an adequate cross-section (see TAB. 1) into the
cable raceway provided (item B – fig. 11) and connect it to the terminal
board as shown in figure 12 (72.72/65.105/105.105/105.65) and figure
26 (60.60).
(60.60)
and
150
engineers
recommended
by
These appliances must also be included in the unipotential system. The
terminal to be used for this purpose is located at the back of the
appliance. It is marked with the symbol TERMINAL FOR THE
UNIPOTENTIAL SYSTEM.
When connection has been completed, check that the supply voltage,
with the appliance running, does not differ from the rated value by
more than ±5%.
WARNING!
supply must have characteristics at least equal to the model with
rubber insulation H05RN-F and must have a rated section suited to
the maximum absorption (see technical data, TAB. 1).
2.5.2.2 ELECTRICAL CONNECTION OF THE LEAVENING
COMPARTMENT
WARNING!
two-pole switch with fuses or an automatic switch suitable for the
values shown on the plate, that provide full disconnection under
mm
overvoltage category III conditions.
NOTE:
The device selected should be in the immediate vicinity
of the appliance and within easy access.
NOTE:
The sheath of the power supply cable must prevent
that the conductors in basic insulation come in contact with the
surrounding metal parts. The ground conductor must be 50mm
longer than the power supply conductors. The supplied presscable
can clamp a cable with a diameter between 10 and 14mm.
The leavening compartment is delivered with the a voltage of 230Vac.
1N 50/60 Hz, as indicated on the rating plate (fig. 2).
To carry out electrical connection, remove the protective cover located
on the left hand rear side of the compartment (fig.13).
The connection cable must be supplied by the installer.
When connecting to the power mains, it is necessary to fit a plug that
complies with the standards and regulations in force.
Insert the cable into the cable raceway provided (item B - fig.14) and
then connect it to the terminal board as illustrated in figure 15.
These appliances must also be included in the unipotential system. The
terminal to be used for this purpose is located at the back of the
appliance.
It
is
marked
UNIPOTENTIAL SYSTEM.
When connection has been completed, check that the supply voltage,
with the appliance running, does not differ from the rated value by
more than ±5%.
WARNING!
supply must have characteristics at least equal to the model with
rubber insulation H05RN-F and must have a rated section suited to
the maximum absorption (see technical data, TAB. 2).
WARNING!
earthed. A special earth terminal has been provided for this purpose on
the connection terminal board (fig. 12-15 and fig.26). It is marked with
the earth symbol and the earth wire must be connected to it.
NOTE:
The manufacturer declines any responsibility in the
the
event of failure to comply with the above safety precautions.
2.5.2.3 VAPOUR
CONNECTION
WARNING!
two-pole switch with fuses or an automatic switch suitable for the
values shown on the plate.
NOTE:
The device selected should be in the immediate vicinity
of the appliance and within easy access.
The vapour aspiration hood is delivered with a voltage of V230 1N
50/60 Hz, as indicated on the rating plate at the side.
UK/3
The flexible wire for connection to the power
The compartment must be fitted with a main
with
the
symbol
TERMINAL
The flexible wire for connection to the power
It is essential that the appliance be properly
ASPIRATION
HOOD
The compartment must be fitted with a main
FOR
THE
ELECTRICAL

Publicidad

loading

Este manual también es adecuado para:

493105065200-i