1. Attaching the suction hose to strainer
Attach the clear suction hose to the suction strainer by pushing
the male threaded end into the rubber coupler on the suction
strainer.
Then, place the strainer in at least 1 in. of water at the lowest
point to be pumped.
NOTE:
Make sure the connection is airtight. An air leak can cause
the pump to run dry.
2. Attaching hoses
Open the bottom cover.
Thread the other end of the suction hose to the inlet of the pump.
Thread a 5/8 in. garden hose (sold separately, 50 ft. max. length) onto the
discharge outlet of the pump.
NOTE:
Always ensure the washer in the hose bib is not
damaged. An airtight seal is necessary for this pump to
operate.
NOTE:
Make sure the end of the outlet hose is not under
water. If the outlet is under water, the pump may not work.
NOTE:
Do not coil or kink the hose.
3. Priming water
Unscrew the priming plug.
Fill water through priming hole as the picture shows until to overflow.
Tighten the priming plug.
6
For Professional Technical Support call 1-844-242-2475